16
Change parameters page 3/3
External input:
Works with Input terminal -
see manual at page 3.
- OFF:
Every signal to Input terminal is ignored.
- External trigger:
gun trigger is disabled and repla-
ced by micro switch connected to Input (SIG and GND)
- Burst-3 trigger:
micro switch connected to Input
(SIG and GND) make 3 burst fi re when it is pressed
.
Gun trigger is still functional.
- AUG trigger:
selector plate detection is disabled.
Gun trigger is set to selector on semi. Micro switch co-
nnected to Input (SIG, GND) is set to selector on auto.
- Empty mag (NO):
Micro switch activates empty ma-
gazine detection, when is connected SIG with GND.
- Empty mag (NC):
Micro switch activates empty ma-
gazine detection, when is disconnected SIG with GND.
- Virtual reload:
Micro switch activates virtual maga-
zine reload, when is connected SIG with GND.
Virtual magazine:
Value sets number of shots (70bb here). Gun will stop shooting when virtual mag. reach 0.
Near empty magazine -
makes 2 short beeps after each shot before virtual mag. is empty.
Reload delay
-
is time when gun can‘t shoot after empty mag. or it is triggered by „Virtual
reload“ (through
input port
- set as fi re mode or
change selector position
- there and back)
Save or Save as:
You can save these parameters under custom name into your app.
FACTORY RESET:
It restores parameters to factory state (password is unchanged).