- 117 -
197895 RCD-2
Index B
11 ONBOARD COMFORT
11.1 AIR CONDITIONING
General points
- The air-conditioning is powered by alternating current.
- The air-conditioning cools the air temperature inside the boat (only when the boat is floating
in water).
- The cooling circuit consists of one or more compressors that operate independently. A
compressor is called "reversible" because it can heat the boat if the seawater temperature
exceeds 13°C.
- In winter, you can programme the dehumidifier function on the air conditioning controls.
- The refrigeration compressors are made by one or two seawater pumps. These pumps are
run on AC voltage and are master controlled by one or two relay boxes.
- Seawater is drained via a through-hull fitting equipped with a valve, located above the
waterline. Each compressor has its own through-hull drainage fitting. It is advisable to check
the flow of water visually once the air conditioning starts running.
Operation
Before starting the engine:
- Open the raw water intake valves and evacuation valves;
- Make sure that the control panel is in the STOP position;
- Use the switch on the chart table to select the power source (shore power or generator).
- If using shore power: plug into the shore power socket;
- If using the generator: before turning on the air conditioning, leave the generator
running for approximately 3 minutes.
- If the seawater pump is deprimed (eg. in case of running aground), carry out the following
procedure:
- Disconnect the discharge hose from the seawater pump by loosening the 2
stainless steel collars;
- Blow air through the pipe using a compressor;
- Re-connect the discharge hose with 2 stainless steel collars.
When the air conditioning is running:
- Switch the air-conditioning circuit-breakers ON.
- Select the temperature of each compressor using the control units.
11
ONBOARD COMFORT
Summary of Contents for LEADER 33 OUTBOARD
Page 1: ...197895 RCD 2 Index B LEADER 33 OUTBOARD VERSION OWNER S MANUAL...
Page 2: ......
Page 10: ......
Page 20: ......
Page 52: ......
Page 61: ...61 197895 RCD 2 Index B Diagram of layout 7 ELECTRICAL SYSTEM...
Page 62: ...62 197895 RCD 2 Index B 7 2 6 Layout of hull wiring looms DC circuit...
Page 63: ...63 197895 RCD 2 Index B 7 2 7 Layout of deck wiring looms DC circuit 7 ELECTRICAL SYSTEM...
Page 64: ...64 197895 RCD 2 Index B 7 2 8 Layout of wiring looms in the deck backing moulding DC circuit...
Page 65: ...65 197895 RCD 2 Index B 7 2 9 Sportop wiring harness plan DC circuit 7 ELECTRICAL SYSTEM...
Page 88: ...88 197895 RCD 2 Index B...
Page 90: ...90 197895 RCD 2 Index B...
Page 92: ...92 197895 RCD 2 Index B Brazil Version 220V 60Hz...
Page 96: ...96 197895 RCD 2 Index B 7 4 6 Layout of hull wiring looms AC circuit...
Page 97: ...97 197895 RCD 2 Index B 7 4 7 Layout of deck wiring looms AC circuit 7 ELECTRICAL SYSTEM...
Page 112: ...112 197895 RCD 2 Index B Fridge Location Galley Cockpit fridge...
Page 132: ......
Page 136: ...136 197895 RCD 2 Index B 12 4 FRESH WATER DISTRIBUTION SYSTEM...
Page 154: ......
Page 170: ......
Page 182: ......
Page 188: ......
Page 196: ......