Commands 45
Error Code
Description
0 ( 0x00 )
No error--OK
1 ( 0x01 )
Invalid command opcode
2 ( 0x02 )
Command packet length mismatch
3 ( 0x03 )
Invalid packet length
4 ( 0x04 )
Invalid command packet parameter
5 ( 0x05 )
EEPROM write failure
6 ( 0x06 )
Switch 1 failure
7 ( 0x07 )
Switch 2 failure
8 ( 0x08 )
Switch 3 failure
9 ( 0x09 )
Switch 4 failure
10 ( 0x0A )
Invalid spare channel
11 ( 0x0B )
Communication interface receive time-out
12 ( 0x0C )
Communication interface transmit time-out
13 ( 0x0D )
Communication packet invalid
14 ( 0x0E )
Communication receive run-on condition
15 ( 0x0F )
Communication transmit run-on condition
16 ( 0x10 )
Communication invalid transmit operation initiated by master
17 ( 0x11 )
Reserved
18 ( 0x12 )
Communication invalid STROBE received
19 ( 0x13 )
RS485 link-layer packet CRC mismatch
20 ( 0x14)
RS485 invalid link-layer packet length
21 ( 0x15)
RS485 invalid link-layer packet type
22 (0x16)
RS485 invalid source address
23 (0x17)
RS485 link-layer packet ACK transmit timeout
24 (0x18)
RS485 link-layer packet ACK receive timeout
25 (0x19)
RS485 link-layer ACK expected but DATA packet received
26 (0x1A)
RS485 unexpected ACK packet received
27 (0x1B)
UART overrun (bytes missed in serial receive)
28 (0x1C)
Undefined error
Summary of Contents for SKB Series
Page 1: ...SKB SERIES FIBEROPTIC SWITCH MODULE User Manual ...
Page 2: ...ii 10109002 Rev 001 August 2001 2001 JDS Uniphase All rights reserved ...
Page 4: ...iv ...
Page 11: ...7 Contents ...
Page 13: ...9 List of Figures ...
Page 15: ...11 List of Tables ...
Page 19: ...4 Safety Information Instructions and Symbols ...
Page 25: ...10 Introduction ...
Page 53: ...38 Operation and Control Instructions ...
Page 91: ...76 Commands ...
Page 111: ...96 Application Notes ...
Page 113: ...98 Service ...