32 Operation and Control Instructions
Timing
When a channel address is strobed in from the data lines, the reset command is strobed in from the
/Reset line. The Error line goes high if the reset function cannot verify the position of the switching
mechanism (Figure 10).
Figure 10: Timing Diagram
Timing Key
The timing key symbols and values are listed in Table 10.
Table 10: Timing Key
Symbol
Minimum
Maximum
tdh, data hold time
20 µs
–
tstr, strobe pulse width
1 µs
–
tmv, switching cycle time
–
0.55 ms
trh, reset hold time
20 µs
–
trst, reset cycle time
–
1.1 s
Busy
Error