Chapter 11
Measure Mode – Sweep Tab
Reverse Alignment
292
DSAM Help User Guide
Rev. 001
Measurement
Information Area
This area includes the test point compensation icon/value, the tilt
value, and the number of users (if using multi-user reverse alignment).
Graph
The graph updates with each new set of sweep data received by the
meter. A tilt line is displayed between the levels at each marker. An
error message automatically is displayed if the sweep telemetry level
is too low.
Graph Information
Bar
This area consists of the start and stop frequencies (as provided by the
sweep plan transmitted from the headend transceiver). If zoom is
active, a zoom icon also is displayed and the start and stop frequen-
cies are updated to match the zoom view.
Marker Status Area
The Marker Status area displays the marker frequency in MHz, the
meter-generated signal level, and the headend measured signal level
frequencies for which the markers are on. The black square around
the frequency indicates the active marker. The delta label between the
level at the meter and the headend is also displayed.
Viewing Reverse
Alignment Results
To view reverse alignment results in different ways
1
Press the
View
softkey.
2
Using the arrow keys, select one of the following:
–
Auto Reference (Shift, 9)
to automatically view measurement
results in the best reference setting on the graph.
Figure 260
Measure Mode – Reverse Alignment
Measurement
Information Area
Graph
Graph Information Bar
Marker Status Area
21128026 R001 DSAM Help User Guide.book Page 292 Thursday, February 5, 2009 2:02 PM