Chapter 9
Measure Mode – Service Tab
DOCSIS
206
DSAM Help User Guide
Rev. 001
5
Using the arrow keys, select one of the following:
–
Range Only
: If the DOCSIS Configuration field is set to Range
Only, only the range results on the DOCSIS results screen is
displayed after you run a DOCSIS test.
–
Range and Registration
: If the DOCSIS Configuration field is
set to Range and Registration, the DOCSIS results screen is
displayed after you run a DOCSIS test. In addition, you can
display the Registration screen from the View menu.
–
Registration with CPE Initialization
: If the DOCSIS Configu-
ration field is set to Registration with CPE Initialization, the
DOCSIS results screen is displayed after you run a DOCSIS
test. In addition, you can run data service tests.
6
Verify that the value in the
DOCSIS Version
field matches the
CMTS you are testing.
7
Verify that the value in the
DOCSIS Security Mode
field matches
the security mode for the CMTS you are testing.
8
Press the
OK
softkey.
Running a
DOCSIS Test
You must build a channel plan prior to running a DOCSIS test.
To run a DOCSIS test
1
Check your
preliminary configurations
(
).
2
Press
Measure
.
3
Press the
Service
softkey.