Chapter 5
Configuring the Meter
Configure – Channel Plan Tab
86
DSAM Help User Guide
Rev. 001
To configure access channels
1
Press
Configure
.
2
Press the
Chan Plan
softkey.
3
Using the arrow keys, select
Downstream Plans
.
4
Press
ENTER
.
5
Using the arrow keys, select the
plan
you want to work with.
6
Press the
Plan
softkey.
7
Using the arrow keys, select
Access Channels
.
8
Press
ENTER
.
9
Using the arrow keys, select the
channel
you want to include.
10
Press the
Select
softkey.
Configuring
Telemetry Frequency
The Telemetry frequency is the frequency used to transmit data from
the headend modem to the DSAM. Telemetry frequency on the DSAM
must match the frequency at which the headend modem (HSM 1000)
is broadcasting. The valid frequency range is between 50 MHz and
1000 MHz.
To configure telemetry frequency
1
Press the
Plan
softkey.
2
Using the arrow keys, select
Telemetry
.
Figure 73
Configure – Select Access Channels
21128026 R001 DSAM Help User Guide.book Page 86 Thursday, February 5, 2009 2:02 PM