Chapter 8
Measure Mode – Basic Tab
Tilt
DSAM Help User Guide
Rev. 001
173
If the marker is on a channel that is the low pilot or is greater in
frequency than the low pilot, High is disabled.
8
Press
ENTER
.
View Menu
To access different functions and shortcuts to other tests
1
Press the
View
softkey.
2
Using the arrow keys, select one of the following options:
–
Auto Reference (Shift, 9)
– Enables you to automatically view
measurement results in the best reference setting on the
graph.
–
5 dB/div
or
10 dB/div
– Enables you to adjust the vertical
resolution of the graph for the best viewing.
–
MiniScan
– Displays the MiniScan screen.
–
Single Channel
– Displays measurements one channel at a
time. First, use the arrow keys to move the marker to the
preferred channel then highlight this option from the View
menu.
–
Full Scan
– Displays the Full Scan screen.
–
Pause
(
Shift, 8
) – Suspends measurement updates.
– Use the left and right arrow keys to move the marker horizon-
tally to the previous or to the next channel. You can also use
the keypad to type the channel number.
NOTE
If a digital channel is selected as either the low or high pilot to be
compared to an analog channel, a warning dialog is displayed with
the following prompt:
Are you sure you want to set a digital channel as a pilot
channel?
– If you answer Yes, that channel is set as the new low or high
pilot.
– If you answer No, the pilot settings are not changed.
NOTE
For best reference setting results you may need to press the Auto
Reference button up to three times.