© 2016 JCM American Corporation
3 2
October, 2016
TBV Transaction Based Validator
8
Double Banknote
Detected
Sensor detected a double Banknote.
[Solution] Check Banknote condition. Clean the Unit.
[Relative Parts] BNF Assignation Sensor, Validation Sensors
If the condition is not resolved, change the above related part or parts.
Calibrate the Unit.
9
Inhibit Setting
The Banknote has been inhibited by DIP Switch Setting or Host Command.
[Solution] Check DIP Switch Block 1 or 3 settings.
[Relative Parts] BNF Circuit Board, CPU
If the condition is not resolved, change the above related part or parts.
Calibrate the Unit.
10
Reject Command
The Banknote was returned in response to a Host Command.
[Solution] Check for proper communications with the Host computer.
[Relative Parts] CPU
If the condition is not resolved, change the above related part or parts.
Calibrate the Unit.
11
Cash Box
Removed
While transporting a Banknote, the Cash Box was removed.
[Solution] Reseat the Cash Box. Check Cash Box Sensors. Clean the Unit.
[Relative Parts] Cash Box Sensor, Cash Box Lock Sensor
If the condition is not resolved, change the above related part or parts.
12
Banknote
Detection
The Sensors detected a Banknote with abnormal timing.
[Solution] Clean the Banknote Path, Belts and Rollers.
[Relative Parts] Entrance, Exit. Validation and Side Sensors, Transport
Belts, Transport Rollers
If the condition is not resolved, change the above related part or parts.
Calibrate the Unit.
13
Banknote Length
The Sensors detected the Banknote Length was longer or shorter than the
specified value.
[Solution] Clean the Banknote path. Check that the Banknote is not
damaged or exhibiting unfit conditions.
[Relative Parts] Rollers, Validation Sensors
If the condition is not resolved, change the above related part or parts.
Calibrate the Unit.
14
Pattern Error 1
The Sensors detected an improper Banknote Pattern.
[Solution] Clean the Banknote path. Check that the Banknote is not
damaged or exhibiting unfit conditions.
[Relative Parts] Validation Sensor
If the condition is not resolved, change the above related part. Calibrate the
Unit.
15
Authentic
Banknote Identity
The Sensors detected a Banknote as invalid.
[Solution] Check that the Banknote is not damaged or exhibiting unfit
conditions. Clean the Transport Path and Sensors.
[Relative Parts] Validation Sensor
If the condition is not resolved, change the above related part. Calibrate the
Unit.
16
Pattern Error 2
The Sensors detected an improper Banknote Pattern.
[Solution] Clean the Banknote path. Check that the Banknote is not
damaged or exhibiting unfit conditions.
[Relative Parts] Validation Sensor
If the condition is not resolved, change the above related part. Calibrate the
Unit.
Table 16
TBV Reject Error Codes (Continued)
Offline
LED Color
Flash
Sequence
Error
Causes and Solutions