72
9.53
SCOM. PORT ASSIGNMENT PROGRAMMING
On G-556 two SCOM ports (SCOM1 and SCOM2) are availables like default ; on
SCOM1 also the connector is installed like default (only for RS232), like option can be
installed others two SCOM ports (SCOM3 and SCOM4, RS232 only).
Each SCOM port can be set by the programmation described in this page, either for
the type of used protocol (RS-232 or RS-485) than for type of device connect to the scom
port (PC, Slip Printer, Scanner, etc...).
These configurations are very useful, because they allow to use the SCOM port
with the already present connector on ECR (SCOM1), in the necessary modality (Eg.
Slip Printer, RS-232, Scanner, etc...), without for this having to make hardware
modification in the machine.
CONFIGURATION:
P
(95)
X/Time
(A B C D)
SUB-TOTAL
#
A : Setting code for SCOM1 (from 0 to C see table below)
B : Setting code for SCOM2 (from 0 to C see table below)
C : Setting code for SCOM3 (from 0 to C see table below)
D : Setting code for SCOM4 (from 0 to C see table below)
SCOM PORTS SELECTION CODES :
CODE
PHERIPHERALS (PROTOCOL)
0
NOT USED
1
Hand Scanner (Scanner mode 1)
2
Fix Scanner (Scanner mode 2)
3
PC connection (RS-232 protocol)
4
PC connection RS-485 (ON-LINE/with polling)
5
External keyboard and/or display
6
GP-965 Slip Printer
7
TM-290 or TM-295 Slip Printer (It is invalid for G3000R)
8
NOT USED
9
CBM530 Kitchen Printers (RS-485 for M-T-P)
A (*)
PC connection RS-485 (OFF-LINE/no polling)
B (*)
EFT (It is valid for G3000R)
C (*)
TM-T88II Kitchen Printer (RS-485 for P-T-P)
*
: A = "Dept. 1"
*
: B = "Dept. 2"
*
: C = "Dept. 3"
Note :
- Same device cannot be set on more than two SCOM ports
- Two scanners of the same type cannot coexist connected to the ECR
- Configuration "3", "4" or "A" of the SCOM cannot coexist
- Default configuration
:
SCOM1 = 3
SCOM2 = 0
SCOM3 = 0
SCOM4 = 0