UM_3201027_BIO100_EN_Rev00
5/20
12V DC
9-14V DC
GND
ground
A
RS485 A
B
RS485 B
LR-
Red LED -
LG-
Green LED -
D1
Data 1
D0
Data 0
Tamper
Tamper Switch(NO)
Tamper
Tamper Switch(NO)
3 Mounting
If the biometric reader is installed and used outdoor, the reader MUST be fitted with
the MC-MINI metal cover available in our accessories in order to protect the sensor
from direct rainfall. The operating temperature of the product is between -20ºC - +
50ºC.
If the reader is installed in an environment where the temperature can drop below
-10ºC or/and if the sensor could only be exposed to direct sunlight, it is strongly
recommended to install the reader inside a third party sealed wall mount box (fitted
with additional heater if very low temperature) to keep a constant sensor level
performance.
JCM cannot guarantee the functionality of the product if measures and advice before
are not followed.
It is also strongly recommended to use double technology biometric readers when use
outdoor to offer first higher security but also the possibility to use different readers
depending on users.
4 Wiring
Red
Black
Pink
Purple
Blue
Gray
Green
Orange
Yellow
White