background image

8

AC POWER REQUIREMENTS  

V

ER

T

EC

®

DP Series line array elements are equipped with a DP multi-channel Crown Class-I power amplifier and dbx™

loudspeaker specific DSP electronics and require appropriate AC power.  

CAUTION:

In compliance with safety agency criteria and proper system operation, it is critical that the system
installer observe all electrical safety practices at all times and provide proper earth grounding for
all AC Power connections.

AC Power Cord-sets

Convenience 120VAC North America NEMA 5-15 Edison type AC plug to PowerCon

®

connector and 240V Europe CEE 7/7

Schuko type AC plug to PowerCon

®

connector cord sets are provided with this V

ER

T

EC

®

DP Series product for light-duty

shop testing or system configuration type use.  

One spare gray Neutrik (P/N NAC3FCB) PowerCon

®

connector is included in the AC Power Cord Set for your convenience

to create a pass-through AC power cable.  To create a pass-through cable the system installer may choose to simply cut off
the AC plug from one of the provided AC cord sets and replace it with the provided Gray PowerCon

®

AC Outlet

connector. Follow the wiring convention indicated in Table 1.  

NOTE:

Fasten bushing by means of a fork wrench 3/4 min. Torque 2.5Nm (1.8lb-ft) to prevent opening by hand.

USER FABRICATED AC POWER DISTRIBUTION 

System owners may choose to fabricate or purchase a custom AC Power cable infrastructure optimized for their specific
V

ER

T

EC

®

DP line array system configuration.  See Table 1 for custom application wiring and connector information.  

NOTE:

Parts not provided.  

CAUTION:

Do not exceed 80% current rating of any AC connector at any time! 

See Table 2 for current draw information. 

Table 1

User Fabricated AC Cable and Connector Information

AC Inlet Cable Connector

Neutrik PowerCon

®

NAC3FCA quick lock 3-pole A-type cable connector for power inlet.

Rated current per contact: 20 A (rms), Rated Voltage: 250VAC

AC Outlet Cable Connector  

Neutrik PowerCon

®

NAC3FCB quick lock 3-pole B-type cable connector for power

outlet. Rated current per contact: 20 A (rms), Rated Voltage: 250VAC

Wiring 

Cable: screw-type terminals or soldering nom. wire size/contact: 2.5 mm

2

/ 14 AWG 

Wiring convention 

Ground –Ground, Neutral – Neutral, AC Hot – AC Hot  

With the two non-interchangeable types of connectors (A-type, B-type) it is impossible to produce a short circuit. Mating
connectors (combination) are identified by mechanical keyways and by color.

Power Connector Coding

A-type (POWER INLET);

Cable connector: Blue 

B-type (POWER OUTLET)

Cable connector: Gray, with Blue bushing 

Table 2

DP3 AC Power Ratings 

Description

120VAC

240VAC

Idle (Sleep Mode)

<35W

Quiescent Power Draw 

<120W

1/8th power pink noise (UL/CSA)

600W, 5A rms

600W, 3.3A rms

1/3rd Power, Pink Noise

10.5 A

5.25 A

Maxiumum Power Draw

4500W

Inrush Current

Inrush current limiting via PTC soft-start

AC Power Module Connectors: 12A Max, 100-120VAC/220-240VAC, 50-60 Hz. Class 1 Wiring

16 AWG (1.5 mm

2

)

Inlet Connector Rating

5A

3.3A

w/16 AWG (1.5 mm

2

)

Outlet Connector Rating

7A

9A

wiring

Summary of Contents for VERTEC DrivePack DP Series

Page 1: ...JBL VERTEC DP Series DrivePack DP3 DPIP Operator s Guide...

Page 2: ...2...

Page 3: ...where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with...

Page 4: ...o alert the user to important operating or maintenance instructions FCC COMPLIANCE NOTICE This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 This...

Page 5: ...Use Part 2 Immunity EN 61000 4 2 1995 A1 1999 A2 2001 Electrostatic Discharge Immunity Environment E2 criteria B 4 kV Contact 8 kV Air discharge EN 61000 4 3 2003 Radiated Radio frequency Electromagn...

Page 6: ...erial and with load impedances of 4 8 or 16 Ohms for low and mid frequency channels and 8 or 16 Ohms for the high frequency channel Package Contents Operator s Guide this document VT48XXDP loudspeaker...

Page 7: ...el is applied iii SOLID illumination indicates thermal protection is in the second stage of protection and amplifier shut down may occur if immediate action is not taken to correct the external reason...

Page 8: ...for their specific VERTEC DP line array system configuration See Table 1 for custom application wiring and connector information NOTE Parts not provided CAUTION Do not exceed 80 current rating of any...

Page 9: ...ages within the rated voltage windows AC POWER MODULE POWER Indicator Blue LED located near power inlet lights when AC power applied Amp READY Indicator Green LED near power inlet on during normal ope...

Page 10: ...f the jacket See Figure 2 2 Open the center Velcro tab and insert through the opening in the module riser See Figure 3 3 Next wrap the left side of the cover around the bottom edge of the riser Insure...

Page 11: ...ge space inside and can accommodate a jacket once the Velcro strip has been unzipped and the jacket has been unwrapped from the module riser trim piece To implement this procedure unhook the second sh...

Page 12: ...authorization from JBL Customer Service Monday through Friday 8 00am 5 00pm Pacific Coast Time In the U S A 800 8JBLPRO 800 852 5776 www jblproservice com On the World Wide Web www jblpro com Outside...

Reviews: