background image

ENGLISH

OPERATION MANUAL

JB SYSTEMS

®

1/64

LED LIGHTBAR 4TC

OPERATION MANUAL

Thank you for buying this JB Systems

®

product. To take full advantage of all possibilities and for your own

safety, please read these operating instructions very carefully before you start using this unit.

FEATURES

This unit is radio-interference suppressed. This product meets the requirements of the current European and
national guidelines. Conformity has been established and the relevant statements and documents have been
deposited by the manufacturer.

This device was designed to produce decorative effect lighting and is used in light show systems.

Stylish and extremely compact powered 4BAR containing 4 ultra thin RGB LED-projectors

Each LED-projector contains 4pcs RGB 3in1 3watt LEDs for exceptional high light output (exceeding the
output of traditional PAR56 300W lamps!)

High quality “constant current” LED technology!

LED-Projector beam angles = 15°

Energy saving: uses only 66W (instead of 1200W for traditional 4x PAR56-300W)

Perfect for mobile applications: only 106cm long and weighs only 7kg!

Many applications possible: Discotheques, DJs, hiring companies, ...

Very smooth RGB color changes thanks to high freq. dimming electronics

0-100% dimming and ultra fast strobe function (no additional strobes needed!)

Excellent built-in programs for wonderful, ever changing, light shows!

Different working modes:

Standalone: automatic or beat synchronized color patterns (optional CA-8 controller possible)

Master/slave mode: up to 42 sets can be used together for wonderful preprogrammed, music
synchronized lightshows.

DMX-controlled (1MSL, 1, 4, 7, 12 or 16 channel mode for maximum flexibility)

Controlling up to 42 units is child’s play using the optional LEDCON 02 remote!

Optional CA-32F foot controller available: perfect for small music bands!

4-digit menu driven display to select all possible functions

Standard 35mm stand adapter included.

A nice and strong carrying bag for easy transport is optionally available.

5m mains cable included.

BEFORE USE

Before you start using this unit, please check if there’s no transportation damage. Should there be any, do
not use the device and consult your dealer first.

Important:

This device left our factory in perfect condition and well packaged. It is absolutely necessary

for the user to strictly follow the safety instructions and warnings in this user manual. Any damage caused
by mishandling is not subject to warranty. The dealer will not accept responsibility for any resulting defects
or problems caused by disregarding this user manual.

Keep this booklet in a safe place for future consultation. If you sell the fixture, be sure to add this user
manual.

Check the contents:

Check that the carton contains the following items:

Operating instructions

LED LIGHTBAR 4TC

5m mains cable

ENGLISH

OPERATION MANUAL

JB SYSTEMS

®

2/64

LED LIGHTBAR 4TC

SAFETY INSTRUCTIONS:

To protect the environment, please try to recycle the packing material as much as possible.

A new light effect sometimes causes some unwanted smoke and/or smell. This is normal and disappears
after some minutes.

To prevent fire or shock hazard, do not expose this appliance to rain or moisture.

To avoid condensation to be formed inside, allow the unit to adapt to the surrounding temperatures when
bringing it into a warm room after transport. Condense sometimes prevents the unit from working at full
performance or may even cause damages.

This unit is for indoor use only.

Don’t place metal objects or spill liquid inside the unit. Electric shock or malfunction may result. If a foreign
object enters the unit, immediately disconnect the mains power.

Locate the fixture in a well ventilated spot, away from any flammable materials and/or liquids. The fixture
must be fixed at least 50cm from surrounding walls.

Don’t cover any ventilation openings as this may result in overheating.

Prevent use in dusty environments and clean the unit regularly.

Keep the unit away from children.

Inexperienced persons should not operate this device.

Maximum save ambient temperature is 40°C. Don’t use this unit at higher ambient temperatures.

The units’ surface temperature may reach up to 85°C. Don’t touch the housing with bare hands during its
operation.

Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging
and servicing.

Allow the device about 10 minutes to cool down before replacing the bulb or start servicing.

Always unplug the unit when it is not used for a longer time or before replacing the bulb or start servicing.

The electrical installation should be carried out by qualified personal only, according to the regulations for
electrical and mechanical safety in your country.

Check that the available voltage is not higher than the one stated on the rear panel of the unit.

The power cord should always be in perfect condition. Switch the unit immediately off when the power cord
is squashed or damaged. It must be replaced by the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.

Never let the power-cord come into contact with other cables!

This fixture must be earthed in order to comply with safety regulations.

Don’t connect the unit to any dimmer pack.

Always use an appropriate and certified safety cable when installing the unit.

In order to prevent electric shock, do not open the cover. Apart from the lamp and mains fuse there are no
user serviceable parts inside.

CAUTION:

To reduce the risk of electric shock, do not remove

the top cover. No user-serviceable parts inside. Refer servicing
to qualified service personnel only.

The lightning flash with arrowhead symbol within the equilateral triangle is intended to alert the
use or the presence of un-insulated “dangerous voltage” within the product’s enclosure that may
be of sufficient magnitude to constitute a risk of electric shock.

The exclamation point within the equilateral triangle is intended to alert the user to the presence
of important operation and maintenance (servicing) instructions in the literature accompanying
this appliance.

This symbol means: indoor use only

This symbol means: Read instructions
This symbol determines: the minimum distance from lighted objects. The minimum distance
between light-output and the illuminated surface must be more than x meters
The device is not suitable for direct mounting on normally flammable surfaces. (suitable only for
mounting on non-combustible surfaces)

CAUTION:

Do not stare at operating lamp.

May be harmful to the eyes.

Summary of Contents for LED LIGHTBAR 4TC

Page 1: ......

Page 2: ......

Page 3: ...rain or moisture To avoid condensation to be formed inside allow the unit to adapt to the surrounding temperatures when bringing it into a warm room after transport Condense sometimes prevents the un...

Page 4: ...with its bracket D Leather washer B LIGHT BAR Leather washer B Wing nut A Repeat this action for the 4 projectors refer to the drawing to see how the 4 panels should be fixed correctly Insert the LED...

Page 5: ...in the display Use DOWN and UP button to select YES blackout or no no blackout mode ENGLISH OPERATION MANUAL JB SYSTEMS 6 64 LED LIGHTBAR 4TC Once the right mode is selected press the ENTER button to...

Page 6: ...3 Positive signal Pin layout XLR 5pin Pin1 GND Pin2 Negative signal Pin3 Positive signal Pins4 5 not used To prevent strange behavior of the light effects due to interferences you must use a 90 to 120...

Page 7: ...ENGLISH OPERATION MANUAL JB SYSTEMS 9 64 LED LIGHTBAR 4TC 7 CHANNEL MODE 12 CHANNEL MODE ENGLISH OPERATION MANUAL JB SYSTEMS 10 64 LED LIGHTBAR 4TC 16 CHANNEL MODE...

Page 8: ...the installation place is free from unwanted persons during servicing Switch off the unit unplug the mains cable and wait until the unit has been cooled down During inspection the following points sh...

Page 9: ...cet appareil la pluie ou l humidit Pour viter une formation de condensation interne laissez l appareil s adapter la temp rature ambiante quand vous la mettez dans une pi ce chauff e apr s le transpor...

Page 10: ...une table Assemblez les 4 projecteurs comme suit 4 trous se trouvent dans la barre m tallique placez le projecteur en face du trou situ en bas de la barre et poussez le boulon du bas vers le haut Resp...

Page 11: ...ppuyez sur la touche MENU jusqu ce que SoUn s affiche l cran Appuyez sur la touche ENTER l affichage se met clignoter Utilisez les touches BAS DOWN et HAUT UP pour s lectionner un des modes canal disp...

Page 12: ...e de bonne qualit Toutes les unit s connect es sont automatiquement allum es comme esclaves REMARQUE IMPORTANTE pour s assurer que tout fonctionne correctement vous devez r gler la LED LIGHTBAR 4TC en...

Page 13: ...R 4TC MODE 4 CANAUX Lorsqu on met les 4 projecteurs de l unit en mode 4CH ils r agissent exactement de la m me mani re que l un des autres projecteurs LED JB SYSTEMS MODE 7 CANAUX FRAN AIS GUIDE D UTI...

Page 14: ...t ma tre UTILISATION D UNE TELECOMMANDE CA 8 Il suffit de connecter cette petite t l commande au connecteur 1 4 de l unit ma tre et vous pourrez contr ler les l ments suivants FONCTIONS TOUCHES ACTION...

Page 15: ...profiteren en voor uw eigen veiligheid lees deze gebruiksaanwijzing zorgvuldig voordat u met dit apparaat start KENMERKEN Dit apparaat is radio interferentie onderdrukt Dit product voldoet aan de eis...

Page 16: ...geschikt voor directe montage op normaal brandbare oppervlakken Alleen geschikt voor montage op onbrandbare oppervlakken OPGELET Kijk niet naar een werkende lamp Het kan schadelijk zijn voor de ogen N...

Page 17: ...4 LED LIGHTBAR 4TC HOE IN TE STELLEN HOOFDMENU Druk op en houd de MENU knop ingedrukt totdat de benodigde optie op de display wordt weergegeven Selecteer de functie met de ENTER knop De display zal kn...

Page 18: ...ngsmodus terug te keren of keer na 8 seconden zonder enige verandering automatisch naar de hoofdfuncties terug Weergave inversie Normale weergave de weergave is leesbaar wanneer het apparaat op de vlo...

Page 19: ...minator aan het eind van de keten gebruiken Gebruik nooit Y splitter kabels dit zal gewoon niet werken Zorg ervoor dat alle apparaten op het lichtnet zijn aangesloten Elk lichteffect in de keten heeft...

Page 20: ...NEDERLANDS HANDLEIDING JB SYSTEMS 35 64 LED LIGHTBAR 4TC 12 KANAALMODUS NEDERLANDS HANDLEIDING JB SYSTEMS 36 64 LED LIGHTBAR 4TC 16 KANAALMODUS...

Page 21: ...elen onttakelen en onderhoud vrij is van ongewenste personen Schakel het apparaat uit ontkoppel het netsnoer en wacht totdat het apparaat is afgekoeld Tijdens de inspectie moeten de volgende punten wo...

Page 22: ...n Minuten Zur Vermeidung von Feuer und Stromschlag Ger t weder Regen noch Feuchtigkeit aussetzen Zur Vermeidung von Kondensation im Inneren des Ger ts bitte nach dem Transport in eine warme Umgebung e...

Page 23: ...h nicht zusammengebaut ist packen Sie alle Teile aus und legten Sie sie auf einen Tisch Montieren Sie die 4 Projektoren wie folgt Auf der Metallleiste sehen Sie 4 L cher Legen Sie den Projektor vor da...

Page 24: ...TBAR 4TC W hlen Sie mit DOWN Abw rts und UP Aufw rts einen der m glichen Kanal Modi On Sound Modus ON Die Show wird ber das interne Mikrofon ausgel st OFF Sound Modus OFF Die Show wird ber die Geschwi...

Page 25: ...alles ordnungsgem funktioniert M SSEN Sie die LED LIGHTBAR 4TC auf den LEdC Kanalmodus einstellen und die automatische Adressvergabe Funktion auf der LEDCON 02 durchf hren bevor Sie den Set das erste...

Page 26: ...4 KANAL MODUS Die 4 Projektoren der Einheit reagieren genau auf die gleiche Weise wie alle anderen JB SYSTEMS LED Projektoren wenn sie in den 4CH Modus geschaltet wurden 7 KANAL MODUS DEUTSCH BEDIENU...

Page 27: ...e end an der Master Einheit verwendet werden MIT DEM CA 8 EASY CONTROLLER Diesen kleinen Controller einfach an der 1 4 Buchse des Hauptger ts anschlie en und dann folgende Funktionen steuern FUNKTIONE...

Page 28: ...Este producto cumple con todas las exigencias de las pautas actuales tanto europeas como nacionales Dicha conformidad ha sido establecida y los dict menes y documentos han sido consignados por el fabr...

Page 29: ...a el montaje directo sobre superficies normalmente inflamables Es adecuado solamente para el montaje sobre superficies no combustibles PRECAUCI N No mire a las l mparas cuando est n encendidas Pueden...

Page 30: ...ndos La estructura del men se muestra a continuaci n ESPA OL MANUAL DE INSTRUCCIONES JB SYSTEMS 56 64 LED LIGHTBAR 4TC Configuraci n de la Direcci n DMX512 Se utiliza para establecer la direcci n de i...

Page 31: ...dor normal Presione el bot n ENTER para alternar entre visualizador normal y inversi n del visualizador Una vez haya seleccionado el modo correcto pulse el bot n ENTER para confirmar Pulse el bot n de...

Page 32: ...a Nunca utilice cables repartidores Y esto simplemente no funcionar Aseg rese de que todas las unidades est n conectadas a la alimentaci n Cada dispositivo de efectos de luces de la cadena tiene que t...

Page 33: ...ESPA OL MANUAL DE INSTRUCCIONES JB SYSTEMS 61 64 LED LIGHTBAR 4TC MODO 12 CANALES ESPA OL MANUAL DE INSTRUCCIONES JB SYSTEMS 62 64 LED LIGHTBAR 4TC MODO 16 CANALES...

Page 34: ...uentra bajo el lugar de instalaci n est libre de personas no autorizadas durante el mantenimiento Apague la unidad desenchufe el cable de alimentaci n y espere hasta que se enfr e Durante la inspecci...

Reviews: