background image

 

  

 Varyscan 6 HMI 575 

 

- 12 - 

 

General Information about DMX512-record 

 
The DMX 512-record is divided in 512 addresses. You have 512 addresses for your disposal. To be able to connect 
different appliances with a DMX-controller, it is necessary to determine the number of DMX-channel for every appliance. 
The occupation of channels of a projector could be like that for example: 
 
 

 

Channel 1 

 

X-Movement 

 

 

Channel 2 

 

Y-Movement 

 

 

Channel 3 

 

Gobo / Effect wheel 

 

 

Channel 4 

 

Colour 

 

 

Channel 5 

 

Shutter / Dimmer 

 

 

Channel 6 

 

Iris / gobo positioning / gobo rotation 

 
In order that not every connected DMX-appliance performs same functions, the appliances are addressed in series; i.e. 
for the first appliance the first six addresses are used (be right for an appliance with six channels), for the second one 
(appliance with 6 channels) the next 6 addresses of all the DMX-addresses are used (see for example Varyscan

®

 6 575 

HMI page 11).  
 
 

Occupation of channels Varyscan

®

 6 575 HMI 

 
 

 

Channel 1 

 

X-movement 

 

 

Channel 2 

 

Y-movement 

 

 

Channel 3 

 

Gobo 

 

 

Channel 4 

 

Colour 

 

 

Channel 5 

 

Dimmer 

 

 

Channel 6 

 

Iris 

 

 

Channel 7 

 

Rotating gobos (positioning and rotating) 

 

 

Channel 8 

 

Effect wheel 

 

 

Channel 9 

 

Focus 

 

 

Channel 10 

 

Shutter 

 

 

Channel 11 

 

Pan-fine 

 

 

Channel 12 

 

Tilt fine 

 

 
channel no. 1 

Pan movement 370° 

channel no. 2  

Tilt movement 270° 

channel no. 3 

Gobo 

gobo   0 (Beam)

 

DMX  000 

031

 

gobo   1 

DMX  032 

063

 

gobo   2 

DMX  064 

095

 

gobo   3 

DMX  096 

127

 

gobo   4 

DMX  128 

159

 

gobo   5 

DMX  160 

255

 

if function DMX-Reset is  at on 

 

gobo   5 

DMX  160 

254 

Reset 

DMX   

 

255 

Channel no. 4

 

Colour

 

colour 0 (white)

 

DMX  000 

007

 

colour 1 (white/red)

 

DMX  008 

015

 

colour 2 (red)

 

DMX  016 

023

 

colour 3 (red/yellow)

 

DMX  024 

031

 

colour 4 (yellow)

 

DMX  032 

039

 

colour 5 (yellow/pink)

 

DMX  040 

047

 

colour 6 (pink)

 

DMX  048 

055

 

colour 7 (pink/green) 

DMX  056 

063 

colour 8 (green) 

DMX  064 

071 

colour 9 (green/orange) 

DMX  072 

079 

Summary of Contents for Varyscan 6 HMI 575

Page 1: ...chtanlagentechnik GmbH Sallersteigweg 15 D 89134 Blaustein Wippingen Telefon 49 0 7304 9617 0 Telefax 49 0 7304 9617 99 http www jb lighting de Varyscan 6 HMI 575 User manual 1 1 software version 0 25...

Page 2: ...Varyscan 6 HMI 575 2...

Page 3: ...ging 7 Pan normal invers 7 Tilt normal invers 7 Pan Tilt normal changed 8 08 16Bit DMX 8 Test mode 8 Stand alone Mode 8 Number of steps 8 Edit step 8 Changing gobo 9 Metal gobos 9 Glass gobos 9 Measur...

Page 4: ...w h e e l c o l o r w h e e l g o b o w h e e l iris i r i s m o t o r s p h e r i c a l l e n s e s t e p p e r m o t o r g o b o w h e e l a s p h e r i c a l l e n s e b u l b b u l b h o l d e r...

Page 5: ...es outline page 4 it should point to the base sheet or to the lid Take care that the bulb is tightened in the holder Warning Never touch the glass of bulb of the 575 HMI bulb itself An adjustment of t...

Page 6: ...2 5 5 0 2 5 5 0 2 5 5 0 2 5 5 0 2 5 5 0 2 5 5 0 2 5 5 E n t e r E n t e r E n t e r E n t e r E n t e r E n t e r D M X M O D E D M X A D D R E S S D M X R E S E T P A N C O L O R T I L T P A N T I L...

Page 7: ...change into the setup menu of the projector DMX mode In the DMX mode range press the key enter until DMX reset on off appears on the display To activate this function press the key to deactivate the...

Page 8: ...which step of your program you want to program By confirmation with the key enter you will come to the selection of the times for the selected step and to the single functions pan tilt gobo colour of...

Page 9: ...in unit into your VS 6 and close the lid If your projector is not prepared for glass gobos or you would like to use more glass gobos you must adapt your projector For this you need a special montage...

Page 10: ...he projector and change it if it is defect 2 The bulb is defect Change it 3 The temperature switch of the projector is released Plug out your Varyscan and after approximately 15 minutes plug it in aga...

Page 11: ...your Varyscan periodically to restore maximum brightness of the projector After having opened the casing as explained above take out the modules and put them on a hard underlay in front of you Now yo...

Page 12: ...nnels the next 6 addresses of all the DMX addresses are used see for example Varyscan 6575 HMI page 11 Occupation of channels Varyscan 6 575 HMI Channel 1 X movement Channel 2 Y movement Channel 3 Gob...

Page 13: ...rotation right slow DMX 225 rotation right fast DMX 255 channel no 8 Effect wheel Open DMX 000 031 artificial light filter DMX 032 063 daylight filter DMX 064 095 Prism DMX 096 111 Shaking prism slow...

Page 14: ...screwing off the 11 screws 1 Display of the main board in the base of the projector After removing the lid of the bottom lid you can see in the middle of the display main board the eprom Change it wi...

Reviews: