Varyscan 6 HMI 575
- 10 -
Standard size: (E -size)
Outside diameter:
37,50 mm
Use diameter:
28,13 mm
Glass-gobo: (E-size)
Outside diameter:
37,50 mm
Use diameter:
28,13 mm
max. thickness
3,00 mm
B Service instructions
Repair of defects
Defect
The appliance does not work at all
1.
Check the 8 ampere fuse for the bulb of the
projector and change it, if it is defect.
2.
Check the 4 ampere fuse for the electronic of the
projector and change it, if it is defect.
The bulb of the applicance does not shine, but
electronics are working,
i.e. motors are working
1. Check the 8 ampere fuse of the projector and
change it, if it is defect.
2. The bulb is defect. Change it.
3. The temperature switch of the projector is released.
Plug out your Varyscan
®
and after approximately 15
minutes plug it in again. Check now, if the ventilator
in the head of the projector works and if it is clean. If
the ventilator is defect, have it exchanged by a
specialist or the producer. If the projector turns off
again, please contact your dealer.
The bulb of the appliance shines but the motors and the
ventilators does not work.
1. Check the 4 ampere fuse for the electronic of the
projector and change it, if it is defect.
2. Check the fuses inside the projector on the display
main-board and change it, if it is defect.
DMX-input does not work
Check the DMX-address adjustment in the display