short circuit current, otherwise the cable and connector will overheat under large current. Refer to NEC for
details.
For best performance, ensure that positive and negative DC wires run closely together avoiding loops.
The manufacturer of the Bypass Diode is Panjit Group, the model of that is 20SQ045, the Maximum
Recurrent Peak Reverse Voltage is 45V and Maximum Average Forward Current is 20A.
Caution: Electrical shock hazard! Do not touch bare conductors or other potentially energized parts.

MAINTENANCE

Jayu Solar recommends the following maintenance items to ensure optimum performance of the module:

Clean the glass surface of the module as necessary. Use water and a soft sponge or cloth for cleaning. A
mild, non-abrasive cleaning agent can be used if necessary. Do not use dishwasher detergent.
Electrical and mechanical connections should be checked periodically by qualified personnel to verify that
they are clean, secure and undamaged.
Check the electrical and mechanical connections periodically to verify that they are clean, secure and
undamaged.
Problems should only be investigated by qualified personnel.
Observe the maintenance instructions for all other components used in the system.

SHUTTING DOWN THE SYSTEM

Completely cover system modules with an opaque material to prevent electricity from being generated while
disconnecting conductors.
Disconnect system from all power sources in accordance with instructions for all other components used in
the system.
The system should now be out of operation and can be dismantled. In doing so, observe the all safety
instructions as applicable to installation.

PRODUCT INFORMATION

Each module has the following product identification:
Label: Refer to IEC standards
Pass: QC Department detailed inspection date and lot tracking information.
Bar code: Each individual module has a unique serial number.

Example:

Do not remove any label. If the label is removed,
the product warranty will no longer be honored by
Jayu.

Typical serial number barcode lable

9

/

13

Summary of Contents for JY360M6-Aa-5

Page 1: ...cted in parallel the total current is equal to the sum of individual module current Keep children well away from the system while transporting and installing mechanical and electrical components Compl...

Page 2: ...Modules can not be used in other excessive and harsh environments such as hail snow sand smoke air pollution soot flammable gases near open flames and highly corrosive substances salt salt spray salt...

Page 3: ...dule type Cell quantity Dimensions mm A B C D E F H I 6 12 1956 992 50 942 1676 1176 M8 35 6 12 1956 992 40 949 1676 1176 M6 28 6 10 1650 992 35 40 50 942 1370 870 M8 35 6 10 1650 992 40 949 1370 870...

Page 4: ...nless steel Caution Guard against contact between different metals Doing so will give rise to electrochemical corrosion 2 Clamp fitting Use a certain number of clamps to fix the modules on the mountin...

Page 5: ...11 14 0 5 2 2 5 3 JYXXXP6 Aa 5 6 12 1956 992 50 490 11 14 0 5 2 2 5 3 JYXXXP6 Ab 5 6 10 1636 992 50 427 11 14 0 5 2 2 5 3 156 Poly silicon JYXXXP6 Ab 5 6 10 1640 992 50 428 11 14 0 5 2 2 5 3 White JY...

Page 6: ...es as shown in figure 2 Use an end clamp to fix the edge module as shown in figure 1 Use hexagon screwdriver to tighten the clamp on the rail securely All clamps include bolts and flange nuts are stai...

Page 7: ...e cases a special support frame may be necessary Module could be used in Fire safety Class C To maintain the corresponding fire prevention level the tilt angle should be no less than 5 in ft 127 mm 30...

Page 8: ...1954381 2 When using grounding clips the grounding conductor should be inserted into the aluminum frame as shown above in Figure 2 and secured using the 8 32 set screw Then use a nut included with th...

Page 9: ...t use dishwasher detergent Electrical and mechanical connections should be checked periodically by qualified personnel to verify that they are clean secure and undamaged Check the electrical and mecha...

Page 10: ...e or expense arising out of or in any way connected with such installation operation use or maintenance No responsibility is assumed by Jayu Solar for any infringement of patents or other rights of th...

Page 11: ...Ab 5 40 22 9 33 32 98 8 93 295 00 18 13 JY290M6 Ab 5 39 90 9 30 32 64 8 87 290 00 17 83 JY285M6 Ab 5 39 86 9 21 32 57 8 75 285 00 17 52 JY280M6 Ab 5 39 56 9 09 32 42 8 62 280 00 17 21 JY275M6 Ab 5 38...

Page 12: ...6 96 9 07 37 92 8 57 325 16 75 JY320P6 Aa 5 46 76 9 00 37 69 8 49 320 16 49 JY315P6 Aa 5 46 37 8 89 37 44 8 41 315 16 23 JY310P6 Aa 5 46 07 8 83 37 21 8 33 310 15 98 JY305P6 Aa 5 45 77 8 77 36 96 8 25...

Page 13: ...6 01 9 22 28 95 8 81 255 17 35 JY250P6 Ac 5 35 71 9 10 28 79 8 68 250 17 01 JY245P6 Ac 5 35 40 9 02 28 57 8 58 245 16 67 JY240P6 Ac 5 35 10 8 95 28 27 8 50 240 16 32 JY235P6 Ac 5 34 82 8 88 28 11 8 37...