Doc. ref :
333130A-EN
2018/01/05
Page 39 / 44
DRAFT R revision5
Receiver
RSRD
16.2.2
Mechanical and environment withstand characteristics
Housing material:
Polyamide 6/6 (PA6/6), glass bead filled
Protection index:
IP 65
Weight:
700 g (complete model with housing)
Operating temperature range:
- 20 °C to + 60 °C
Storage temperature range:
- 30 °C to + 70 °C
Connection: Spring
– type plug in connectors
Minimum Cable rated voltage of 250 VAC
Conductor wire sections to be observed on T-blocks :
J1 & J2
............0,2 mm² to 2,5 mm²
J3
...................0,25 mm² to 1,5 mm²
Antenna:
¼ wave,
VUA001A
plug-in on BNC connector
Cable lead-out:
- M16 cable gland for safety relays (tightening torque to be respected = 2N.m)
- M25 cable gland for power supply and other signals (tightening torque to be respected = 5N.m)
Electrical characteristics
Power supply voltage :
24 VDC SELV/PELV +/- 20%
In according to chapter 9.4 of IEC / UL 61010-1 3rd edition, the product must be powered by class 2 power supply or by limited energy
Max. consumption :
120 mA (non-loaded static outputs)
Max. consumption protected by fuse :
500mA
Safety relay outputs :
Contacts :
3 NO forcibly guided contacts
Tripping time (reaction) :
•
Local emergency stop reaction time : 60 ms
•
Active stop time following activation of transmitter RSEF safety input : 55 ms + Safety Delay
•
Enabling switch reaction time : 30 ms
•
Passive stop time (1) :
- 300 ms, for emergency stop according to EN 60204-1:2016
to
- 1.5 s, for a safety stop according EN 60204-32:2008 para 9.2.7, If the requirement of the risk analysis allows it
•
Safety Delay (1) : - 0 to 10 sec set by step of 1 sec (default 0s)
Max. switching capacity :
US/Canada specification
according to UL 60947-4-1A
3.6 A 30 VAC
3.6 A 30 VDC
Resistive load
SAT 85 °C
2 A 30 VAC
Pilot Duty load
T. ambient 25 °C
1.5 A 30 VAC
Pilot Duty load
T. ambient 60 °C
VDE
3.6 A 250 VAC
3.6 A 30 VDC
Per AC15 : 2 A / 240 V for 1 NO contact loaded EN 60947-5-1:2004/A1:2009
Per AC15 : 1.5 A / 240 V for all contacts loaded EN 60947-5-1:2004/A1:2009
Static outputs (not secure) :
Number and type of outputs :
4 PNP outputs
Output voltage:
24 VDC, 100 mA max.
Indication :
3 indicator lights
(1) = The passive stop time and the safety delay can be set with dedicated software*.
* The dedicated programming software is available on JAY Electronique website. The use of the programming software is protected
by a password, this password is only delivered to a skilled person “level 2” (a person who was trained by JAY Electronique, and
who is authorized to modify RSRD receiver parameters).