Doc. ref :
333130A-EN
2018/01/05
Page 30 / 44
DRAFT R revision5
10
Diagnosis
Transmitter
RSEF
: Messages given by indicator lights V1 and V2
10.1
To determine possible faults, the transmitter has two indicator lights on the front panel,
V1
and
V2
.
Normal operation :
Transmitter status
V1
(green)
V2
(red)
Message indicated by
indicator lights
Action
After transmitter power up
OFF
ON for 1 second,
then OFF
Transmitter initialisation phase
/
On
“manual” restart mode, after
transmitter power up or after
deactivation/activation of safety
input
ON
OFF
On standby for action on
restart button (restart mode
programmed for « manual »)
- Press restart button to place transmitter
in radio transmission mode
After transmitter power up or
when restart button is pressed
(restart function in « auto »
mode)
Flash
OFF
RADIO transmission
/
In radio channel configuration
mode
Flashes indicate
number of
units
of
new radio channel
Flashes indicate
number of
tens
of
new radio channel
Radio channel number
indication
/
2 flashes
2 flashes
Channel inaccessible with
10mW
Change radio channel (40 to 64)
Abnormal operation :
Transmitter
status
V1
(green)
V2
(red)
V3
(orange)
Message indicated by
indicator lights
Solution
After transmitter
power up
OFF
OFF
OFF
Power supply problem,
transmitter not supplied
- Check power supply voltage
- Check condition of protection fuse
After transmitter
power up
Or
after activation of
safety input
OFF
OFF
ON
SIM card read error
- SIM card not present,
- SIM card incorrectly inserted or removed from its
location
- SIM card faulty (must be replaced)
Incorrect wiring of safety input
Check the wiring of safety input between terminals
Nb. 7 and Nb. 10.
4 flashes
4 flashes
ON
« Input check » function has
detected an error
Check the transmitter wiring : NO contacts of inputs
(nb 1 to nb 10) and restart button must be in «idle»
position when transmitter is powered up.
6 flashes
6 flashes
ON
Incorrect wiring of safety input
Check the wiring of safety input between terminals
Nb. 8 and Nb. 9.
Operating
5 flashes
5 flashes
ON
Configuration micro-switches
changed
Re-position configuration micro-switches to their
initial positions and activate then deactivate the
safety input to clear the error.
Operating
6 flashes
6 flashes
ON