Mounting, installation and commissioning
Follow all instructions described in this manual, in particular chapter safety.
This machine is CE marked. When placing multiple machines in one line, the entire line must be properly CE
marked before using this machine. Up to CE Marking of the line, commissioning of this machine is prohibited.
5.1
Placement
The machine must be placed on a flat surface, with sufficient weight capacity. Install the machine so that there is
enough space left for service providing, safe instructions and / or cleaning, maintenance and / or inspections. Put the
brakes on the castors before the machine is turned on.
This machine is not suitable to be used in the open air. Electrical components are only splashproof. Keep the
machine away from rain and moisture. When using the machine in a humid location is unavoidable, you
should use an RCD.
5.2
Facilities to take care of by the user
Prior to delivery of the machine, the required materials and facilities (air, power, substrate, etc.) needs to be present
within 3 meters of machine.
Required power supply: 400 Volt, 3 Phase + N Earth. (N. America: 208/220V 60Hz.).
5.3
Mounting / Connecting
If applicable, the components supplied are to be mounted on the machine. Make sure that the moving parts are
free. If the machine is complete, it can be connected (by a competent person) to the power supply.
Keep hands, hair, loose clothing and / or jewellery away from moving parts of the machine. Wear
appropriate clothing without loose parts. Wear non-slip work shoes.
As long as the machine is on, no connection or safety devices may be removed. The machine may only be
used when all protective devices and safety-related facilities are available and ready for use.
5.4
Check elevator rotation direction
Check the rotation direction of the elevator before you start working
with the machine.
Procedure:
1.
Connect the power cable.
2.
Start the elevator.
a.
Turn off the main switch.
b.
Press the reset button emergency stop circuit.
c.
Start the elevator with the elevator button.
3.
Check the direction of rotation of the elevator.
a.
The desired rotation direction is shown in this picture.
4.
Stop the elevator by turning elevator switch off.
5.
Switch the main switch off.
6.
When rotation direction is incorrect:
a.
Remove the plug from the socket.
b.
Open the plug and switch 2 of the 3 phases in the plug. This should only be carried out by suitably
qualified personnel.