46
LGG100-GG Operator’s Manual
www.javad.com
S E T U P A N D M E A S U R I N G
DGPS Measuring with the LGG100-GG
3
7. Click on
Configuration->Receiver
(Figure 3-3).
Figure 3-3. Configuration->Receiver
8. Click the
Set all parameters to defaults
button located at the bottom of
the
Receiver Configuration
screen.
9. Select the
Positioning
tab and set the
Position Masks
,
Elevation mask
parameter to 15 (Figure 3-4).
Figure 3-4. Receiver Configuration – Positioning
10. Select the
Base
tab and set the following parameters (Figure 3-5 on
•
GPS/GLO at one time
- enable
•
Antenna position
- enter Lat, Lon, and Alt values. Do one of the fol-
lowing:
–If known, type in the values.
–Click
Get from receiver
.
–Enable
Averaged
and enter the in seconds, then click
Apply
.