38
LGG100-GG Operator’s Manual
www.javad.com
C O N F I G U R A T I O N
MinPad Configuration
2
“Specified file” refers to the file name entered in the
Always
append to file
parameter.
Table 2-1. Data Recording Parameter Behavior
Before Power
Failure
Enabled Radio Button Results
Off
On
Always
1
receiver data
logged to file
specified.
Data logging will not
resume when power is
restored.
receiver will resume
data logging to the
same file when power
is restored.
receiver will resume
data logging to the
same file when power
is restored.
2
receiver data
logged to
default file.
Data logging will not
resume when power is
restored.
A new log file will
open when power is
restored and data will
log to this file.
A new log file will
open when power is
restored and data will
log to this file.
3
File specified;
receiver data
logging not
started.
No file will open with
this name.
Data logging will not
start when power is
restored.
No file will open with
this name.
Data logging will not
start when power is
restored.
A log file with this
name will open and
data logging will start
after power is restored.
4
No file speci-
fied; receiver
data logging
off.
Data logging will not
start when power is
restored.
Data logging will not
start when power is
restored.
A log file with a
default name will open
and data logging will
start after power is
restored.
Also, if
Always
is enabled, your receiver will automatically start logging
data (to a newly created or an existing file) in the following three cases:
• After pressing the
Power
key to turn on the unit.
• After resetting the unit (with PCView or the
Reset
key).