DGPS Measuring with the LGG100-GG
11. Click
Tools->Reset receiver
and wait until the specified interval (span)
completes. Examine the Base coordinates on the Base tab; they should
correspond to the coordinates obtained from the average.
12. Click
Refresh
if the coordinates are zeros.
Notice:
The reference geodetic coordinates you specify on this tab relate to the antenna
L1 phase center.
Figure 3-5. Base Tab Configuration