Jason’s Standard Edition MicroSilk
®
-AirMasseur
®
system
features the best in luxury bathing for the leisure bath
industry. To assure that your bath functions properly, the
MicroSilk
®
and blower pump control boxes must be prop-
erly connected.
NOTe: For 120v systems, the power cord for the
MicroSilk control box must be plugged into a 120v, 20
amp GFCI dedicated circuit. The power cord for the
AirMasseur control box must be plugged into a 120v,
15 amp GFCI dedicated circuit.
THe AIRMASSeUR
®
CONTROL BOX
The blower and keypad must be plugged into the proper
receptacles for correct operation of the MicroSilk
®
-
AirMasseur
®
system. See
Figure 9
for connections:
(F) 8-pin mini-DIN terminal for the MicroSilk
®
-AirMasseur
®
keypad. (K) The power cord for the blower control box
must be connected into the proper GFCI dedicated circuit
for the system (see note above). (I) Pre-wired power cord
from blower to the control box (H). (E) Six-pin mini-DIN
terminal for optional LED light.
THe MICROSILK
®
CONTROL BOX
The MicroSilk
®
unit and water level sensor must be
plugged into the proper receptacles for correct operation
of the system. See
Figure 9
for connections: (A) The
power cord for the MicroSilk
®
pump control box must be
plugged into the proper GFCI dedicated circuit for the
system (see note above). (C) The MicroSilk
®
pump’s power
cord will need to be plugged into the control box (B). Refer
to the ELECTRICAL section of this manual for connecting
the pump to the control box. (D) Two-pin terminal for
installation of the water sensor to the MicroSilk
®
control box.
MICROSILK
®
-AIRMASSeUR
®
CONTROL BOX CONNeCTIONS
STANDARD eDITION
MICROSILK
®
-AIRMASSeUR
®
Figure 9
Jason’s Premier Edition MicroSilk
®
-AirMasseur
®
system
incorporates all the features of the Standard Edition
system and includes the benefits of an ozone sanitation
system, and an LED Chromatherapy light. To assure that
your bath functions properly, the equipment control boxes
must be properly connected.
NOTe: For 120v systems, the power cord for the
MicroSilk
®
control box must be plugged into a 120v,
20 amp GFCI dedicated circuit. The power cord for
the AirMasseur
®
control box must be plugged into a
120v, 15 amp GFCI dedicated circuit.
THe AIRMASSeUR
®
CONTROL BOX
The blower and keypad must be plugged into the proper
receptacles for correct operation of the MicroSilk
®
-
AirMasseur
®
system. See
Figure 10
for connections: (F)
8-pin mini-DIN terminal for the MicroSilk
®
-AirMasseur
®
keypad. (K) The power cord for the blower control box
must be connected into the proper GFCI dedicated circuit
for the system (see note above). Pre-wired power cords
from blower (I) and ozone unit (G) to the control box (H).
(E) Six-pin mini-DIN terminal for optional LED light.
PReMIeR eDITION
MICROSILK
®
-AIRMASSeUR
®
NOTe: This diagram (Figure 9) also applies to 50 Hz,
240v equipment, controls, and power supply systems.
except that the MicroSilk
®
and blower junction box
must be connected into one dedicated 240v, 20 Amp
GFCI circuit.