INSTALLATION INSTRUCTIONS (cont.)
4. Clamp the MicroSilk
®
Jet Line to the MicroSilk
®
Discharge Barb using the clamp provided on the
tubing. Assure the MicroSilk
®
Jet Line will allow proper
drainage to the Jets
(Figure 6)
. The discharge hose
must have a continuous drop from the discharge barb
to the jet fitting.
5. Clamp the MicroSilk
®
Suction Line to the MicroSilk
®
Suction Barb using the clamp provided on the tubing.
Assure the MicroSilk
®
Suction Line will allow proper
drainage to the suction
(Figure 7)
. The suction hose
must have a continuous drop from the suction barb to
the suction fitting.
6. Clamp the MicroSilk
®
Drain Line to the MicroSilk
®
Drain Barb using the clamp provided on the tubing.
Assure the MicroSilk
®
Drain Line will allow proper
drainage to the drain fitting
(Figure 7)
. The drain hose
must have a continuous drop from the drain barb to
the drain fitting.
Figure 6
Figure 7
Caution: Confirm all tubing is fully engaged on
its respective barb and its clamp has secured the
tubing to the barb.
7. The bottom of the Pump Mount must be secured and
level with the bottom of the bath, it is recommended
removable fasteners be used in case any future
servicing is required.
8. Continue bath installation per the Jason Owner’s
Manual Installation, Operation, and Maintenance
guide.
Remote Mounting of Air Blower
The Jason AirMasseur
®
system has been factory installed
following E.T.L. Guidelines. During installation, if remote
mounting of the blower is desired or required, the following
procedures should be followed.
NOTe: Do not remote mount the blower more than
15 feet (457cm) away from the air inlet of the bath.
Choose a location as close as possible to the bath to
assure maximum efficiency.
1. The installer must determine the layout of the piping;
exact remote mount location; and service access
before beginning any work. Use 1.5” (38mm) ABS
or PVC plastic tubing. Locate the blower in an area
accessible for servicing.
NOTe: A 15-foot extension
replacement cable set can be purchased from
your Jason supplier, if needed. To ensure
proper functioning of the system, avoid remote
mounting in a location which requires more than
six (6) piping direction changes. A 90° direction
change should be made up of two 45° elbows for
maximum efficiency.
2. If the blower has been factory installed, disconnect the
blower from the air bath plumbing by removing the two
(2) screws on the check valve outlet and disconnect
the short piece of flex pipe between the check valve
and the elbow by removing the two (2) screws in the
elbow. (Omit this step on baths where the blower is not
factory installed and remote mounting is required.)
3. Install the blower in the remote location. The remote
mount locations’ ambient air temperature should
remain at approximately 22°C (72°F) for optimum air
heating.
4. Make sure the blower is well ventilated. The blower
mount should be attached firmly to the floor. Piping
between the remote blower location and the bath
can be insulated using a minimum of 1/2" (13mm)
thick insulation. Attach new piping to the elbow of the
existing piping.