instALLAtiOn instRuctiOns (cont.)

ELEctRicAL

electrical  power  Supply:   

These  instructions  are  written 

assuming 60Hz, 120v power supply.  Special notations are also 
included for 50Hz 240v pump, control equipment, and power 
supply.

WA R N I N G

:  

v e R I F I CAT I O N   O F   e l e C T R I CA l 

ReqUIReMeNTS MUST be MADe beFORe INSTAllATION. 

ReFeR TO The eqUIpMeNT lAbelS FOR vOlTAGe AND 

FReqUeNCy ReqUIReMeNTS.

NOTe: verify that the electrical service matches either the 

120v (or 240v for Signature edition) system requirements 

for this bath.

NOTe:  The  bath  is  designed  for  indoor  use  only.  The 

electrical  equipment  must  not  be  exposed  to  direct  or 

indirect water or moisture contact. The electrical equipment 

must also be protected from dust and other airborne debris 

before, during, and after installation.

electrical  Service: 

1. 

A  licensed  electrician  must  provide 

the  “dedicated”  electrical  service  protected  by  a  GFCI. 
The  location  of  the  GFCI  must  be  at  least  five  (5)  feet 
(152  cm)  away  from  the  inside  surface  of  the  bath, 
accessible for regular testing. Use copper conductors only.

 

DANGeR  —  RISK  OF  eleCTRIC  ShOCK:  Connect 

only to a circuit protected by a Ground Fault Circuit 

Interrupter  (GFCI).  In  the  unlikely  occurrence 

of  a  current  imbalance  in  the  power  conductors, 

the  GFCI  will  interrupt  the  power  to  the  bath. 

WARNING: The eleCTRICAl SeRvICe TO The GFCI 

MUST  NOT  be  INTeRRUpTeD  by  ANy  CONTROl 

DevICe. lIKeWISe, The eleCTRICAl SeRvICe FROM 

The GFCI TO The bATh CONTROl ShOUlD be DIReCT 

AND NOT INTeRRUpTeD by A SWITCh. NeveR USe A 

SWITCh IN CONJUNCTION WITh A CONTROl DevICe. 

ThIS WIll vOID The MANUFACTUReR’S WARRANTy. 

G R O U N D I N G  

I S  

R e q U I R e D 

2. 

The  unit  should  be  installed  by  a  qualified 

service  representative  and  properly  grounded. 

I N S TA L L   S E R V I C E   C O N N E C T I O N   A T 

3. 

L E A S T   6 ”   (15 c m)   A B OV E   S U B   F L O O R . 
 

All lOCAl AND STATe eleCTRICAl AND plUMbING 

CODeS  MUST  be  ObSeRveD.

  Where  there  are  no 

local  codes  the 

National  electric  Code  (NeC)

  and

 

Uniform  plumbing  Code  (UpC) 

shall  be  observed.  It 

is  the  responsibility  of  the  installer/owner  to  determine 

specific code compliance prior to installation of the product. 

Standard/premier  edition  Control  box  (120v). 

4. 

The 

MicroSilk generator unit is shipped separate from the bath. 
Follow the instructions for the

 MicroSilk pump Assembly 

Field Installation 

in the

 Installation 

section of this owner’s 

manual (instructions are also packaged with the MicroSilk 
unit packaging). The blower is prewired to the control box. 
The control boxes have a 36” (91cm) cord with plug end. The 
MicroSilk and blower control boxes are mounted on a stand 
that is temporarily secured to the packing board for shipping. 
These  boxes  must  remain  on  the  control  box  bracket  so 
that  the  two  boxes  can  communicate  properly  through 
their  infrared  communication  feature.  During  installation, 
the  control  box  bracket  and  controls  must  be  positioned 
horizontally  and  located  to  permit  access  for  inspection 
and servicing. The MicroSilk pump’s power cord will need 
to be plugged into the control box.  Connect the blower’s 
male NEMA plug to the female NEMA plug of the control 
box’s  load  line.    The  MicroSilk  control  must  be  plugged 
into a dedicated 120v, 20A, 60Hz, GFCI protected circuit 
and the blower control must be plugged into a dedicated 
120v,  15A,  60Hz,  GFCI  protected  circuit. 

(See  Figure  9)

 

Standard/premier  edition  Control  box  (240v). 

5. 

The 

MicroSilk generator unit is shipped separate from the bath. 
Follow the instructions for the

 MicroSilk pump Assembly 

Field Installation 

in the

 Installation 

section of this owner’s 

manual (instructions are also packaged with the MicroSilk 
unit packaging). The blower is prewired to the control box. 
The control boxes have a 36” (91cm) cord with plug end. The 
MicroSilk and blower control boxes are mounted on a stand 
that is temporarily secured to the packing board for shipping. 
These  boxes  must  remain  on  the  control  box  bracket  so 
that  the  two  boxes  can  communicate  properly  through 
their  infrared  communication  feature.  During  installation, 
the  control  box  bracket  and  controls  must  be  positioned 
horizontally and located to permit access for inspection and 
servicing. The MicroSilk pump’s power cord will need to be 
plugged into the control box.  Connect the pump’s male J+J 
plug to the female J+J plug of the control box’s load line.  
The MicroSilk control must be plugged into a dedicated 240v 
20A, 50 Hz, GFCI protected circuit and the blower control 
must be plugged into another dedicated 240v, 15A, 50 Hz, 
GFCI protected circuit.

 (See Figure 9) 

Signature edition Control box. 

6. 

The MicroSilk generator 

unit is shipped separate from the bath. Follow the instructions 
for the

 MicroSilk pump Assembly Field Installation 

in the

 

Installation 

section  of  this  owner’s  manual  (instructions 

are also packaged with the MicroSilk unit packaging). The 
blower is prewired to the control box. The control boxes have 
a 36” (91cm) cord with plug end. The MicroSilk and blower 
control boxes are mounted on a stand that is temporarily 
secured to the packing board for shipping. These boxes must 
remain on the control box bracket so that the two boxes can 
communicate properly through their infrared communication 

Summary of Contents for BY630

Page 1: ...s responsibility Damage sustained in transit is the responsibility of the carrier If damage is discovered If the carton shows sign of damage inspect the product before accepting and describe the prob...

Page 2: ...cm 236 66 x 36 x 20 5 39 36 x 17 in 47 4 168 x 91 x 52 148 91 x 43 cm 231 72 x 36 x 20 5 45 36 x 17 in 47 6 183 x 91 x 52 170 91 x 43 cm 232 60 x 42 x 20 5 49 36 x 17 in 43 5 152 x 107 x 52 185 91 x 4...

Page 3: ...oor or the skirt will not fit properly 100 Silicone with mildew resistant properties should 2 be applied between the water resistant backer board and the deck of the bath NOTE If you use a tile flange...

Page 4: ...hanges A 90 direction change should be made up of two 45 elbows for maximum efficiency If the blower has been factory installed disconnect the 2 blower from the air bath plumbing by removing the two 2...

Page 5: ...lconnectionsonthedischargeside are tight See Figure 7 Assure the MicroSilk Jet Flex Hose will allow proper drainage to the jets All hoses must haveacontinuousdropfromthesaturationtanktothejets Note Ve...

Page 6: ...er is prewired to the control box The control boxes have a 36 91cm cord with plug end The MicroSilk and blower control boxes are mounted on a stand that is temporarily secured to the packing board for...

Page 7: ...ctoryinstalledwiring Allbuilding materialsandwiringshouldberoutedawayfromtheequipment or other heat producing components of the unit Figure 9 Figure 9A NOTE The load neutral terminal is not used There...

Page 8: ...acrylic surface during installation to minimize cleanup and prevent surface damage WATER TESTING Before finishing the installation it is recommended that the bath be water tested and the plumbing test...

Page 9: ...RMASSEUR Jason s Premier Edition MicroSilk AirMasseur system incor porates all the features of the Standard Edition system and includesthebenefitsofanozonesanitationsystem andanLED Chromatherapylight...

Page 10: ...ensor must be plugged into the proper receptacle for correct operation of the MicroSilk AirMasseur system See Figure 12 for connections A The junction box for the MicroSilk blower control boxes must b...

Page 11: ...r blower with heater and three 3 massage modes Continuous Wave or Pulse The system also includes a Chromatherapy mood light Automatic Ozone System that will be operated any time the blower is powered...

Page 12: ...es to 10 minutes During the two minute purge pressing the Blower On Off icon will stop the purge Signature Edition Daily Purge The daily purge can be activated through the customized settings of the S...

Page 13: ...Speeds icon is used to increase or de crease the blower speed once the blower is On Press and hold the icon to decrease the blower speed until the desired intensity is reached then release Press and...

Page 14: ...and holding the key for more than 5 seconds during the purge idle period LED Light Icon Hold the key for less than two 2 seconds to turn the lights Off or On Hold the key for more than two 2 seconds...

Page 15: ...be found on the front page of this manual or on the small card adhered to the back of the bath just above the equipment HUMIDITY Warning Avoid high humidity levels in your home Mold mildew fungi and b...

Page 16: ...to cool down Check service wire size c Refer to Jason Customer Service d Fill to recommended level Pump does not turn off after set time elapses a Wiring error or control problem a Refer to installer...

Page 17: ...circulatory system problems or diabetes should consult a physician before using a therapy bath G Personsusingmedicationshouldconsultaphysicianbeforeusingatherapybathsincesomemedicationmayinducedrowsin...

Page 18: ...rnational Inc 501 771 4477 Page 18 of 18 Customer Service 800 255 5766 Copyright 2011 Jason International Jason International Inc 8328 MacArthur Drive North Little Rock Arkansas 72118 www jasoninterna...

Reviews: