instALLAtiOn instRuctiOns (cont.)
ELEctRicAL
electrical power Supply:
These instructions are written
assuming 60Hz, 120v power supply. Special notations are also
included for 50Hz 240v pump, control equipment, and power
supply.
WA R N I N G
:
v e R I F I CAT I O N O F e l e C T R I CA l
ReqUIReMeNTS MUST be MADe beFORe INSTAllATION.
ReFeR TO The eqUIpMeNT lAbelS FOR vOlTAGe AND
FReqUeNCy ReqUIReMeNTS.
NOTe: verify that the electrical service matches either the
120v (or 240v for Signature edition) system requirements
for this bath.
NOTe: The bath is designed for indoor use only. The
electrical equipment must not be exposed to direct or
indirect water or moisture contact. The electrical equipment
must also be protected from dust and other airborne debris
before, during, and after installation.
electrical Service:
1.
A licensed electrician must provide
the “dedicated” electrical service protected by a GFCI.
The location of the GFCI must be at least five (5) feet
(152 cm) away from the inside surface of the bath,
accessible for regular testing. Use copper conductors only.
DANGeR — RISK OF eleCTRIC ShOCK: Connect
only to a circuit protected by a Ground Fault Circuit
Interrupter (GFCI). In the unlikely occurrence
of a current imbalance in the power conductors,
the GFCI will interrupt the power to the bath.
WARNING: The eleCTRICAl SeRvICe TO The GFCI
MUST NOT be INTeRRUpTeD by ANy CONTROl
DevICe. lIKeWISe, The eleCTRICAl SeRvICe FROM
The GFCI TO The bATh CONTROl ShOUlD be DIReCT
AND NOT INTeRRUpTeD by A SWITCh. NeveR USe A
SWITCh IN CONJUNCTION WITh A CONTROl DevICe.
ThIS WIll vOID The MANUFACTUReR’S WARRANTy.
G R O U N D I N G
I S
R e q U I R e D
2.
The unit should be installed by a qualified
service representative and properly grounded.
I N S TA L L S E R V I C E C O N N E C T I O N A T
3.
L E A S T 6 ” (15 c m) A B OV E S U B F L O O R .
All lOCAl AND STATe eleCTRICAl AND plUMbING
CODeS MUST be ObSeRveD.
Where there are no
local codes the
National electric Code (NeC)
and
Uniform plumbing Code (UpC)
shall be observed. It
is the responsibility of the installer/owner to determine
specific code compliance prior to installation of the product.
Standard/premier edition Control box (120v).
4.
The
MicroSilk generator unit is shipped separate from the bath.
Follow the instructions for the
MicroSilk pump Assembly
Field Installation
in the
Installation
section of this owner’s
manual (instructions are also packaged with the MicroSilk
unit packaging). The blower is prewired to the control box.
The control boxes have a 36” (91cm) cord with plug end. The
MicroSilk and blower control boxes are mounted on a stand
that is temporarily secured to the packing board for shipping.
These boxes must remain on the control box bracket so
that the two boxes can communicate properly through
their infrared communication feature. During installation,
the control box bracket and controls must be positioned
horizontally and located to permit access for inspection
and servicing. The MicroSilk pump’s power cord will need
to be plugged into the control box. Connect the blower’s
male NEMA plug to the female NEMA plug of the control
box’s load line. The MicroSilk control must be plugged
into a dedicated 120v, 20A, 60Hz, GFCI protected circuit
and the blower control must be plugged into a dedicated
120v, 15A, 60Hz, GFCI protected circuit.
(See Figure 9)
Standard/premier edition Control box (240v).
5.
The
MicroSilk generator unit is shipped separate from the bath.
Follow the instructions for the
MicroSilk pump Assembly
Field Installation
in the
Installation
section of this owner’s
manual (instructions are also packaged with the MicroSilk
unit packaging). The blower is prewired to the control box.
The control boxes have a 36” (91cm) cord with plug end. The
MicroSilk and blower control boxes are mounted on a stand
that is temporarily secured to the packing board for shipping.
These boxes must remain on the control box bracket so
that the two boxes can communicate properly through
their infrared communication feature. During installation,
the control box bracket and controls must be positioned
horizontally and located to permit access for inspection and
servicing. The MicroSilk pump’s power cord will need to be
plugged into the control box. Connect the pump’s male J+J
plug to the female J+J plug of the control box’s load line.
The MicroSilk control must be plugged into a dedicated 240v
20A, 50 Hz, GFCI protected circuit and the blower control
must be plugged into another dedicated 240v, 15A, 50 Hz,
GFCI protected circuit.
(See Figure 9)
Signature edition Control box.
6.
The MicroSilk generator
unit is shipped separate from the bath. Follow the instructions
for the
MicroSilk pump Assembly Field Installation
in the
Installation
section of this owner’s manual (instructions
are also packaged with the MicroSilk unit packaging). The
blower is prewired to the control box. The control boxes have
a 36” (91cm) cord with plug end. The MicroSilk and blower
control boxes are mounted on a stand that is temporarily
secured to the packing board for shipping. These boxes must
remain on the control box bracket so that the two boxes can
communicate properly through their infrared communication