background image

Jason International, Inc.  •  

 

501.771.4477  

 

 

 

Page 3 of 18

 

 

 

 

Customer Service :  800.255.5766 

Copyright © 2011 Jason International.

instALLAtiOn instRuctiOns (cont.)

instALLAtiOn

 

each bath is provided with a cardboard bath well 

protector that should be kept in the unit during the 

installation and throughout the bathroom construction 

process.  

Overflow drains, fill spouts, and valves must be 

installed according to the instructions herein.

See the USeR MAINTeNANCe INSTRUCTIONS section 

of this owner’s manual, prior to Installation, for humidity 

and mold prevention suggestions.

Finish Frame 

1. 

A finish frame under the shell rim should also 

always be constructed to support the bath deck and insure 
proper drainage toward the bath well. This frame is not 
intended to support the full bath weight

 (see Figures 1 & 2). 

 

Jason  offers  a  removable  lateral  skirt  for  most  baths. 
The  skirts  are  available  in  matching  acrylic  colors  and 
provide  convenient  access  to  bath  equipment  as  well 
as  an  excellent  finished  appearance.  However,  if  Ja-
son’s  lateral  skirt  is  not  used,  an  access  panel  MUST 
be  provided  to  enable  final  electrical  connections  and 
service.  Please  refer  to  the  minimum  recommended 
access  panel  size  in

  Table  1  -  Specifications. 

 

If a Jason lateral skirt is to be used, the bath deck must 
be leveled at 20.5” (52cm) from the support floor or the 
skirt will not fit properly.

100%  Silicone  with  mildew  resistant  properties  should 

2. 

be applied between the water resistant backer board and 
the deck of the bath. 

NOTe: If you use a tile flange kit, 

modify the framing to support the bath lip as shown 

in Figure 1.

A minimum ventilation opening of 2” x 4” (5 x 10 cm) for 

3. 

the blower is required, and should be designed to draw in 
indoor ambient air at a minimum of 22°C (72°F).

Install the drain and overflow assembly to the bath shell 

4. 

according to the instructions provided with the drain and 
position the bath in the area of intended installation.

Finish plumbing rough-in of drain and overflow assembly. 

5. 

At this time, considerations should be made for the posi-
tion and mounting of the faucet set, as well as all related 
plumbing. 

Remove  the  packing  board  before  installing 

6. 

the  bath. 

The  bath  is  equipped  with  separate  bath 

equipment  support  bases  which  are  joined  for  ship-
ment  with  packing  boards.  Detach  the  packing  board 
from  the  bath  and  from  underneath  the  equipment.

 

 

WARNING: ANy MODIFICATION TO The eqUIpMeNT 

IS NOT ReCOMMeNDeD AND WIll vOID The MANU-

FACTUReR’S WARRANTy.

Install the bath level for proper drainage. 

7. 

Jason baths 

are designed to be supported at the base of the bath. If the 
floor is smooth and level, the baths’ Level Form™ Base will 
provide proper drainage and support 

(See Figure 3).

SILICONE BEAD

TILE

DRYWALL

DRYWALL

TILE

  OPTIONAL

TILE FLANGE

        KIT  

  OPTIONAL

INTEGRATED

    TILE LIP

   1" X 2"

SUPPORT

SCREW

Figure 1

Figure 2

Figure 3

Summary of Contents for BY630

Page 1: ...s responsibility Damage sustained in transit is the responsibility of the carrier If damage is discovered If the carton shows sign of damage inspect the product before accepting and describe the prob...

Page 2: ...cm 236 66 x 36 x 20 5 39 36 x 17 in 47 4 168 x 91 x 52 148 91 x 43 cm 231 72 x 36 x 20 5 45 36 x 17 in 47 6 183 x 91 x 52 170 91 x 43 cm 232 60 x 42 x 20 5 49 36 x 17 in 43 5 152 x 107 x 52 185 91 x 4...

Page 3: ...oor or the skirt will not fit properly 100 Silicone with mildew resistant properties should 2 be applied between the water resistant backer board and the deck of the bath NOTE If you use a tile flange...

Page 4: ...hanges A 90 direction change should be made up of two 45 elbows for maximum efficiency If the blower has been factory installed disconnect the 2 blower from the air bath plumbing by removing the two 2...

Page 5: ...lconnectionsonthedischargeside are tight See Figure 7 Assure the MicroSilk Jet Flex Hose will allow proper drainage to the jets All hoses must haveacontinuousdropfromthesaturationtanktothejets Note Ve...

Page 6: ...er is prewired to the control box The control boxes have a 36 91cm cord with plug end The MicroSilk and blower control boxes are mounted on a stand that is temporarily secured to the packing board for...

Page 7: ...ctoryinstalledwiring Allbuilding materialsandwiringshouldberoutedawayfromtheequipment or other heat producing components of the unit Figure 9 Figure 9A NOTE The load neutral terminal is not used There...

Page 8: ...acrylic surface during installation to minimize cleanup and prevent surface damage WATER TESTING Before finishing the installation it is recommended that the bath be water tested and the plumbing test...

Page 9: ...RMASSEUR Jason s Premier Edition MicroSilk AirMasseur system incor porates all the features of the Standard Edition system and includesthebenefitsofanozonesanitationsystem andanLED Chromatherapylight...

Page 10: ...ensor must be plugged into the proper receptacle for correct operation of the MicroSilk AirMasseur system See Figure 12 for connections A The junction box for the MicroSilk blower control boxes must b...

Page 11: ...r blower with heater and three 3 massage modes Continuous Wave or Pulse The system also includes a Chromatherapy mood light Automatic Ozone System that will be operated any time the blower is powered...

Page 12: ...es to 10 minutes During the two minute purge pressing the Blower On Off icon will stop the purge Signature Edition Daily Purge The daily purge can be activated through the customized settings of the S...

Page 13: ...Speeds icon is used to increase or de crease the blower speed once the blower is On Press and hold the icon to decrease the blower speed until the desired intensity is reached then release Press and...

Page 14: ...and holding the key for more than 5 seconds during the purge idle period LED Light Icon Hold the key for less than two 2 seconds to turn the lights Off or On Hold the key for more than two 2 seconds...

Page 15: ...be found on the front page of this manual or on the small card adhered to the back of the bath just above the equipment HUMIDITY Warning Avoid high humidity levels in your home Mold mildew fungi and b...

Page 16: ...to cool down Check service wire size c Refer to Jason Customer Service d Fill to recommended level Pump does not turn off after set time elapses a Wiring error or control problem a Refer to installer...

Page 17: ...circulatory system problems or diabetes should consult a physician before using a therapy bath G Personsusingmedicationshouldconsultaphysicianbeforeusingatherapybathsincesomemedicationmayinducedrowsin...

Page 18: ...rnational Inc 501 771 4477 Page 18 of 18 Customer Service 800 255 5766 Copyright 2011 Jason International Jason International Inc 8328 MacArthur Drive North Little Rock Arkansas 72118 www jasoninterna...