tROubLE shOOting guiDE

If you believe the unit to be within the warranty period, you must contact 

Jason Customer Service: 

1-800-255-5766

 with the bath’s Product and Serial numbers before work is started.

 

All warranty repairs must be authorized by Jason before work is started.

 
FOR SERVICE, ALWAYS CONTACT YOUR DEALER OR AUTHORIZED SERVICE CENTER

WARNING: Always turn off power at the main electrical service panel when servicing the bath.

WARRANTy ReGISTRATION: Register you product’s warranty online at www.jasoninternational.com

MICrOsIlK PuMP sYsTeM

sYMPTOMs

POssIBle Causes

reCOMMenDeD aCTIOn

MicroSilk system fails to oper-

ate.

a)     No power to the MicroSilk unit.

b)     Motor is not plugged in.

c)     Touch Control — insufficient water 

in bath.

a)     Reset circuit breakers and GFCI if tripped. Check fuses 

and replace if bad.

        Check voltage at motor when control is on. If no voltage, 

the control is defective. If voltage is present, motor is 

defective.

b)     Make sure plug is fully inserted into the outlet.

c)     Fill bath to recommended level (4” above jets).

Pump operates, but no Micro 

Bubbles are injected into water.

a)     Venturi clogged.

b)     Float valve no operating

a)     Refer to installer/dealer.

b)     Refer to installer/dealer.

Pump operates, but water is 

not being pumped.

a)     Suction or discharge blocked.

b)     Suction air leak. 

(System usually 

surges.)

a)     Remove obstruction.

b)     Make sure connection is tight on suction side 

of the pump.

Pump does not manually shut 

off.

a)     Digital or Touch Control defective.

 

a)     Refer to installer / dealer.

Pump shuts off by itself, or 

before set time elapses. 

a)     Internal filter restricting flow

b)     Pump motor overheated and 

thermal protection device 

deactivated motor. 

(Possibly low 

voltage.)

c)     GFCI tripped.

d)     Water level fell below recom-

mended level.

a)     Clean internal screen filter

b)     Make sure motor air cooling vents are not blocked, 

clear and allow motor to cool down.

 (Check service & 

wire size.)

c)     Refer to Jason Customer Service.

d)     Fill to recommended level.

Pump does not turn off after 

set time elapses.

a)     Wiring error or control problem.

a)     Refer to installer / dealer.

Pump will not turn off when 

water is drained from the bath. 

a)      Water level sensor wires or ribbon 

cables are shorted.

a)     Inspect all sensor wires or ribbon cables for exposed or 

touching wires. Separate touching wires and replace ex-

posed wires. If pump continues, replace water level sensor.

Pump leaks at shaft.

a)     Damaged or defective shaft seal.

a)     Refer to installer / dealer.

LED Light will not operate

a)    Light bulb is  loose in the socket.

a)    Access light bulb and assure that it is properly installed in 

the socket

air Masseur Blower system

sYMPTOMs

POssIBle Causes

reCOMMenDeD aCTIOn

Blower system won’t operate.

a)  No power to air bath unit.
b)  Blower Motor is not plugged in.
c)  Keypad disconnected.

a)  Reset circuit breakers and check GFCI.  Check fuses and 

replace if bad.

b)  Make sure plug is fully inserted into the outlet.
c)  Check and reconnect if necessary.

Blower shut off by itself or before 
time elapses.

a)  Blower motor overheated and thermal 

protection device deactivated motor 
(possibly low voltage).

b)  GFCI tripped.

a)  Check that blower has suffcient ventillation and that the in-

take into the blower is not blocked.  Clear and allow motor 
to cool down. (Check service & wire size.)

b)  Refer to installer/dealer.

Circuit breaker trips repeatedly.

a)  Defective breaker.
b)  Short circuit between bath and blower 

breaker box.

c)  Other items are connected to the same 

circuit.

a)  Replace breaker.
b)  Refer to installer/dealer.
c)  Refer to installer/dealer.

Blower does not shut off.

a)  Defective keypad or timer.

a)  Refer to installer/dealer.  Replace keypad or control.

Air bath does not function prop-
erly while in the pulse or wave 
mode (Signature Edition).

a)  Blower speed setting is set too low.

a)  Change to a mid-range air speed setting before switching 

over to wave or pulse modes.

Standard Edition Purge cycle 
won’t operate.

a)  Purge cycle was disabled.

a)  Remove power to the bath, either by the circuit breaker or 

by unplugging and replugging the blower from the supply 
outlet.

Summary of Contents for BY630

Page 1: ...s responsibility Damage sustained in transit is the responsibility of the carrier If damage is discovered If the carton shows sign of damage inspect the product before accepting and describe the prob...

Page 2: ...cm 236 66 x 36 x 20 5 39 36 x 17 in 47 4 168 x 91 x 52 148 91 x 43 cm 231 72 x 36 x 20 5 45 36 x 17 in 47 6 183 x 91 x 52 170 91 x 43 cm 232 60 x 42 x 20 5 49 36 x 17 in 43 5 152 x 107 x 52 185 91 x 4...

Page 3: ...oor or the skirt will not fit properly 100 Silicone with mildew resistant properties should 2 be applied between the water resistant backer board and the deck of the bath NOTE If you use a tile flange...

Page 4: ...hanges A 90 direction change should be made up of two 45 elbows for maximum efficiency If the blower has been factory installed disconnect the 2 blower from the air bath plumbing by removing the two 2...

Page 5: ...lconnectionsonthedischargeside are tight See Figure 7 Assure the MicroSilk Jet Flex Hose will allow proper drainage to the jets All hoses must haveacontinuousdropfromthesaturationtanktothejets Note Ve...

Page 6: ...er is prewired to the control box The control boxes have a 36 91cm cord with plug end The MicroSilk and blower control boxes are mounted on a stand that is temporarily secured to the packing board for...

Page 7: ...ctoryinstalledwiring Allbuilding materialsandwiringshouldberoutedawayfromtheequipment or other heat producing components of the unit Figure 9 Figure 9A NOTE The load neutral terminal is not used There...

Page 8: ...acrylic surface during installation to minimize cleanup and prevent surface damage WATER TESTING Before finishing the installation it is recommended that the bath be water tested and the plumbing test...

Page 9: ...RMASSEUR Jason s Premier Edition MicroSilk AirMasseur system incor porates all the features of the Standard Edition system and includesthebenefitsofanozonesanitationsystem andanLED Chromatherapylight...

Page 10: ...ensor must be plugged into the proper receptacle for correct operation of the MicroSilk AirMasseur system See Figure 12 for connections A The junction box for the MicroSilk blower control boxes must b...

Page 11: ...r blower with heater and three 3 massage modes Continuous Wave or Pulse The system also includes a Chromatherapy mood light Automatic Ozone System that will be operated any time the blower is powered...

Page 12: ...es to 10 minutes During the two minute purge pressing the Blower On Off icon will stop the purge Signature Edition Daily Purge The daily purge can be activated through the customized settings of the S...

Page 13: ...Speeds icon is used to increase or de crease the blower speed once the blower is On Press and hold the icon to decrease the blower speed until the desired intensity is reached then release Press and...

Page 14: ...and holding the key for more than 5 seconds during the purge idle period LED Light Icon Hold the key for less than two 2 seconds to turn the lights Off or On Hold the key for more than two 2 seconds...

Page 15: ...be found on the front page of this manual or on the small card adhered to the back of the bath just above the equipment HUMIDITY Warning Avoid high humidity levels in your home Mold mildew fungi and b...

Page 16: ...to cool down Check service wire size c Refer to Jason Customer Service d Fill to recommended level Pump does not turn off after set time elapses a Wiring error or control problem a Refer to installer...

Page 17: ...circulatory system problems or diabetes should consult a physician before using a therapy bath G Personsusingmedicationshouldconsultaphysicianbeforeusingatherapybathsincesomemedicationmayinducedrowsin...

Page 18: ...rnational Inc 501 771 4477 Page 18 of 18 Customer Service 800 255 5766 Copyright 2011 Jason International Jason International Inc 8328 MacArthur Drive North Little Rock Arkansas 72118 www jasoninterna...