InsPeCTIOn

Inspect the unit prior to installation. In the event of a 

problem, DO NOT install the unit.

  

All components are factory assembled to the bath and the 
unit is water tested and inspected prior to leaving Jason 
International, Inc.

If the carton shows sign of damage, inspect the product 
before accepting and describe the problem on the Bill of 
Lading.

NOTe: Transportation and insurance from Jason’s 

factory are the buyer’s responsibility.

Damage sustained in transit is the responsibility of the 

carrier.

 If damage is discovered, 

If  the  carton  shows  sign  of  damage,  inspect 

the product before accepting and describe the 

problem on the Bill of lading.

the carrier must be immediately notified in writing with a 
request for a representative to inspect the unit. Failure of 
the carrier to respond should be reported to the seller and 
carrier. Always file a freight claim promptly.

The installer is responsible for insuring that the unit is 
free from defects or shipping damage. In the event of a 
problem, DO NOT install the unit. 
Jason International is not responsible for damage that 
might have been avoided by inspection or testing prior to 
installation.

Damage to the unit during installation will not be covered 
by warranty and is the responsibility of the installer. ALL 
WARRANTY CLAIMS ON ACRYLIC SURFACE DAMAGE 
MUST BE MADE PRIOR TO INSTALLATION. Inspect 
plumbing and bath surface for missing or damaged 
components. Alert your dealer of any discrepancies.

To protect the unit from damage keep the bath in the 
carton until ready for installation.

Summary of Contents for BY630

Page 1: ...s responsibility Damage sustained in transit is the responsibility of the carrier If damage is discovered If the carton shows sign of damage inspect the product before accepting and describe the prob...

Page 2: ...cm 236 66 x 36 x 20 5 39 36 x 17 in 47 4 168 x 91 x 52 148 91 x 43 cm 231 72 x 36 x 20 5 45 36 x 17 in 47 6 183 x 91 x 52 170 91 x 43 cm 232 60 x 42 x 20 5 49 36 x 17 in 43 5 152 x 107 x 52 185 91 x 4...

Page 3: ...oor or the skirt will not fit properly 100 Silicone with mildew resistant properties should 2 be applied between the water resistant backer board and the deck of the bath NOTE If you use a tile flange...

Page 4: ...hanges A 90 direction change should be made up of two 45 elbows for maximum efficiency If the blower has been factory installed disconnect the 2 blower from the air bath plumbing by removing the two 2...

Page 5: ...lconnectionsonthedischargeside are tight See Figure 7 Assure the MicroSilk Jet Flex Hose will allow proper drainage to the jets All hoses must haveacontinuousdropfromthesaturationtanktothejets Note Ve...

Page 6: ...er is prewired to the control box The control boxes have a 36 91cm cord with plug end The MicroSilk and blower control boxes are mounted on a stand that is temporarily secured to the packing board for...

Page 7: ...ctoryinstalledwiring Allbuilding materialsandwiringshouldberoutedawayfromtheequipment or other heat producing components of the unit Figure 9 Figure 9A NOTE The load neutral terminal is not used There...

Page 8: ...acrylic surface during installation to minimize cleanup and prevent surface damage WATER TESTING Before finishing the installation it is recommended that the bath be water tested and the plumbing test...

Page 9: ...RMASSEUR Jason s Premier Edition MicroSilk AirMasseur system incor porates all the features of the Standard Edition system and includesthebenefitsofanozonesanitationsystem andanLED Chromatherapylight...

Page 10: ...ensor must be plugged into the proper receptacle for correct operation of the MicroSilk AirMasseur system See Figure 12 for connections A The junction box for the MicroSilk blower control boxes must b...

Page 11: ...r blower with heater and three 3 massage modes Continuous Wave or Pulse The system also includes a Chromatherapy mood light Automatic Ozone System that will be operated any time the blower is powered...

Page 12: ...es to 10 minutes During the two minute purge pressing the Blower On Off icon will stop the purge Signature Edition Daily Purge The daily purge can be activated through the customized settings of the S...

Page 13: ...Speeds icon is used to increase or de crease the blower speed once the blower is On Press and hold the icon to decrease the blower speed until the desired intensity is reached then release Press and...

Page 14: ...and holding the key for more than 5 seconds during the purge idle period LED Light Icon Hold the key for less than two 2 seconds to turn the lights Off or On Hold the key for more than two 2 seconds...

Page 15: ...be found on the front page of this manual or on the small card adhered to the back of the bath just above the equipment HUMIDITY Warning Avoid high humidity levels in your home Mold mildew fungi and b...

Page 16: ...to cool down Check service wire size c Refer to Jason Customer Service d Fill to recommended level Pump does not turn off after set time elapses a Wiring error or control problem a Refer to installer...

Page 17: ...circulatory system problems or diabetes should consult a physician before using a therapy bath G Personsusingmedicationshouldconsultaphysicianbeforeusingatherapybathsincesomemedicationmayinducedrowsin...

Page 18: ...rnational Inc 501 771 4477 Page 18 of 18 Customer Service 800 255 5766 Copyright 2011 Jason International Jason International Inc 8328 MacArthur Drive North Little Rock Arkansas 72118 www jasoninterna...