13
CONTROLS
Front view Jasic Cut 61 and 81
1. Digital ammeter, displays the preset and actual current
when cutting
2. Power indictor, is lit when the machine is switched on
3. Temperature indicator, when this LED is on it indicates
that the temperature inside the machine is too high
and the machine is under over heating protection
status. Allow machine to cool down
4. Pressure gauge
5. Current control: Allows the user to set the required
current demand
6. 2T/4T torch trigger latch selection switch: A useful
function when carrying out longer cuts, when cutting in
4T mode you can remove your finger off the torch
trigger and the arc will remain on until you either press
the torch trigger again or you remove the plasma arc
away from the material being cut
7. Gas test switch and cutting indicator
8. Torch connector, the plasma torch connection (see
page 16 for fitting instructions)
9. Work return connector (35/50mm Socket)
10. Remote arc start signal
11. Arc voltage feedback signal
Rear view Jasic Cut 61 and 81
12. Air supply inlet
13. Input power cable
14. Mains ON/OFF switch