12. Turn on the machine, and it
appears normal, but the
malfunction LED turns on once
welding is carried out.
a. The connecting cable matching socket
CON11 on control PCB PK-05-A4 with
the output bypass is in loose connection.
b. Loose contact exists in MOSFET
VT1-VT24 on top PCB PM-04-A3 or
rectifying diode U1/U24 on center PCB
PD-13-B0.
c. Some part on control module PK-03-A1 is
damaged.
a. Check.
b. Check with a multi-meter.
c. Check if the chip U2 or audion Q9
on PK-03-A1 is damaged.
13. Turn on the machine, and
there is HF.
a. Some parts in manual switch control
circuit are damaged.
b. The connecting cable matching socket
CON8 on control panel PK-31-A0 with
socket CON4 on bottom PCB PZ-35-A0
is in loose connection, or chip U1 on
control panel PK-31-A0 is damaged.
a. Check with a multi-meter if chip
U8 or diode D14/D18 on control
panel PK-31-A0 is damaged.
Disconnect the connecting cable
matching the socket CON9,
short-circuit both terminal of
socket CON9 and check if the
manual switch board PH-10-A1 is
short-circuited.
b. Check.
14. Incessant HF exists when
welding is carried out.
a. The relay RELAY1, audion Q1, diode D5,
MOSFET VT1 on HF PCB PZ-35-A0 or
chip U1 on control panel PK-31-A0 is
damaged.
b. The connecting cable matching socket
CON13 on control panel PK-31-A0 with
socket CON5 on control PCB PK-05-A4
is in loose connection.
a. Check and replace it if necessary.
b. Check.