19. No AC output in AC mode.
a. The AC/DC conversion switch on the
panel is damaged.
b. Some part on the control panel PK-31-A0
is damaged.
c. Some part on the secondary drive PCB
PK-09-A3 is damaged.
a. Check.
b. Check if the diode D9/D2/D1, chip
U6, audion Q2 or potentiometer
VR4 on control panel PK-31-A0 is
damaged.
c. Check with a multi-meter if chip
U2/U4/U8/U9/U3, audion Q1-Q8
or zener diode Z1/Z2/Z3/Z4 on
drive PCB is damaged.
20. No AC sound when welding
in AC mode.
a. The value of the resistor matching socket
CON1 on inverter PCB PN-05-A2 varies.
b. The MOSFET VT13, rectifying diode
D1/D3, resistor R14/R13 or zener diode
Z3 on inverter PCB PN-05-A2 is
damaged.
a. Check and replace it if necessary.
b. Check and replace it if necessary.
21. Press the welding torch
switch, there is gas out, the
show value of the meter is
invariable, there is only small
current, and the pre-flow time
is variable.
a. The connecting cable matching socket
CON11 on control panel PK-31-A0 with
socket CON2 on control PCB PK-05-A4
is in loose connection.
b. Some part on control panel PK-31-A0 is
damaged.
a. Check.
b. Check if chip U5, audion Q3/Q4 or
potentiometer VR7 on control
panel PK-31-A0 is damaged.
22. When the pulse conversion
switch is at no-pulse state, in
ARC/TIG mode, the welding
current is invariable, and there
is only maximum current.
a. The diode D24 on control panel
PK-31-A0 is damaged.
a. Check and replace it if necessary.