background image

notice to operators, maintenance

and cleanup personnel

Model 1000--FS

page 3 of 16

PRODUCTS CORPORATION

33 ANDERSON ROAD, MIDDLETOWN, CONNECTICUT 06457--4926
UNITED STATES OF AMERICA E--MAIL.

[email protected]

TEL. 860--347--7271 FAX. 860--347--6978 WWW

.jarvisproducts.com

®

JARVIS

6207001::::

NOTICE TO OPERATORS, MAINTENANCE AND CLEANUP PERSONNEL

REMOVE ANY MALFUNCTIONING TOOL FROM SERVICE

REPORT ANY PROBLEMS TO YOUR SUPERVISOR

1. Disconnect

all hydraulic hoses and shut the power off in accordance with OSHA’s lockout/tagout pro-

cedures (29 CFR 1910.147) before making any blade changes.

2. Disconnect

all hydraulic hoses and shut the power off in accordance with OSHA’s lockout/tagout pro-

cedures (29 CFR 1910.147) before performing any repair or maintenance.

3. Disconnect

all hydraulic and hoses and shut the power off -- or have all hydraulic hoses disconnected

and the power shut off -- in accordance with OSHA’s lockout/tagout procedures (29 CFR 1910.147)
before performing any cleanup.

4. Disconnect

all hydraulic hoses and shut the power off when the tool is not being used.

5. Clean up

any spilled or leaked hydraulic fluid.

6. Always

wear eye protection in accordance with OSHA’s eye and face protection requirement (29 CFR

1910.133).

7. Never

put fingers, hands or other parts of the body on the blade or within the cutting path of the tool.

8. Never

allow people to walk in front of the tool during its use.

9. Never

allow people to hold/restrain the carcass.

10. Test

the tool prior to use or daily.

Depress

each trigger separately and the tool should not start.

Depress

one trigger, then pause one second and depress the other trigger and the tool should not start.

Repeat

this procedure reversing the triggers.

Depress

both triggers simultaneously and the tool should start.

With the tool running, release one trigger and the tool should stop.

Repeat

this procedure holding the

other trigger.

If the tool malfunctions, remove it from service and report or repair it immediately

.

11. Never

depress the triggers unless you want to use the tool.

12. Never

make modifications or alterations to the tool.

Report or replace any missing or illegible labels

.

Keep hands clear.

Summary of Contents for 1000-FS

Page 1: ...ydraulic Power Unit 460 230V 4027042 Balancer 4042035 Notice to Employer and Safety Director 2 Notice to Operators Maintenance and Cleanup Personnel 3 Parts Diagram and List 4 Specifications 10 Instal...

Page 2: ...or s give one copy to the maintenance foreman and give one copy to the sub contract cleanup internal cleanup foreman Additional copies will be provided upon request 5 The tool is designed and intended...

Page 3: ...cleanup 4 Disconnect all hydraulic hoses and shut the power off when the tool is not being used 5 Clean up any spilled or leaked hydraulic fluid 6 Always wear eye protection in accordance with OSHA s...

Page 4: ...rew Cup Pt 1 28 1019075 Handle 1 29 1055482 Pan Head Screw with item 31 4 30 1017081 Danger Label with item 31 1 ITEM PART NO PART NAME QTY 31 1024050 Blade Guard 9 inch 1 1024223 Blade Guard 9 in Chi...

Page 5: ...Back up Ring 2 59 1035170 O ring 2 60 1042116 Hanger 1 61 1017061 Name Plate Label 1 62 1055274 Drive Screw 4 63 1018077 Trigger Lever 1 64 1035123 Thread Boot Seal 1 65 1010535 Dowel Pin 1 66 101907...

Page 6: ...1 11 1035500 O ring 2 12 1004357 Extraction Washer 3 13 1021157 Needle Bearing 4 14 1020272 Idler Shaft 1 15 1026187 Gear 2 16 1010408 Dowel Pin 2 17 1055939 Socket Head Cap Screw 6 18 1004306 Split...

Page 7: ...PART NAME QTY 18 1055296 Hex Head Screw 2 19 1055482 Pan Head Slotted Screw 4 20 1042224 Handle Brkt w items 19 21 1 21 1017081 Danger Label 1 22 1055326 Hex Head Screw 2 23 1012056 Clamp 1 24 104217...

Page 8: ...er Assembly Triangular 1 1034059 Filter only Triangular 1034005 Filter Assembly Spin on 1 1034006 Filter only Spin on 1 13 1022029 Dir Control Valve 115V 1 1022174 Dir Control Valve 230V ITEM PART NO...

Page 9: ...Board Panel 1 6 1016348 Electrical Enclosure 1 7 1072091 Replacement Fuse 115V 1 1063852 Replacement Fuse 230V 8 1063079 Wire Terminal Ring 1 9 1017012 Danger Label 1 ITEM PART NO PART NAME QTY Figure...

Page 10: ...clean dry work area and provide adequate space on all sides of the unit for maintenance access to all components 2 Remove filler breather cap item 9 Figure E page 8 and fill the power unit oil reserv...

Page 11: ...L jarvis products corp snet net TEL 860 347 7271 FAX 860 347 6978 WWW jarvisproducts com JARVIS 6207001 Return Line Right Side Tools or Pressure Line Left Side Tools Figure 1 Installation Diagram Elec...

Page 12: ...1 Position the 1000 FS 4 2 Depress both triggers simultaneously to start the tool and make the cut Always use two hands when starting and stopping the tool 4 2 1 Make the cut with a firm steady motio...

Page 13: ...crew Blade Retaining Flange Dowel Pins Holes for Dowel Pins Shaft and Pin Assembly Lip Dowel Pin Holes Washer Notched Area Hub 3 1 Clean and inspect circular blade Refer to sec tions 4 and 5 for blade...

Page 14: ...d place shaft and pin assembly item 2 into blade retain ing flange 6 8 Hold bearing cover item 5 and lightly tap the end of shaft and pin assembly item 2 with ny lon mallet to separate ball bearings i...

Page 15: ...r item 47 blade guard item 31 and front handle assembly 8 4 1 For 1000 FS models with adjustable han dles remove blade guard and hex head screws item 7 Figure D page 7 Separate front handle bracket it...

Page 16: ...F AMERICA E MAIL jarvis products corp snet net TEL 860 347 7271 FAX 860 347 6978 WWW jarvisproducts com PRODUCTS CORPORATION PRODUCTS CORPORATION 33 ANDERSON ROAD MIDDLETOWN CONNECTICUT 06457 4926 UNI...

Reviews: