notice to operators, maintenance
and cleanup personnel
Model 1000--FS
page 3 of 16
PRODUCTS CORPORATION
33 ANDERSON ROAD, MIDDLETOWN, CONNECTICUT 06457--4926
UNITED STATES OF AMERICA E--MAIL.
TEL. 860--347--7271 FAX. 860--347--6978 WWW
.jarvisproducts.com
®
JARVIS
6207001::::
NOTICE TO OPERATORS, MAINTENANCE AND CLEANUP PERSONNEL
REMOVE ANY MALFUNCTIONING TOOL FROM SERVICE
REPORT ANY PROBLEMS TO YOUR SUPERVISOR
1. Disconnect
all hydraulic hoses and shut the power off in accordance with OSHA’s lockout/tagout pro-
cedures (29 CFR 1910.147) before making any blade changes.
2. Disconnect
all hydraulic hoses and shut the power off in accordance with OSHA’s lockout/tagout pro-
cedures (29 CFR 1910.147) before performing any repair or maintenance.
3. Disconnect
all hydraulic and hoses and shut the power off -- or have all hydraulic hoses disconnected
and the power shut off -- in accordance with OSHA’s lockout/tagout procedures (29 CFR 1910.147)
before performing any cleanup.
4. Disconnect
all hydraulic hoses and shut the power off when the tool is not being used.
5. Clean up
any spilled or leaked hydraulic fluid.
6. Always
wear eye protection in accordance with OSHA’s eye and face protection requirement (29 CFR
1910.133).
7. Never
put fingers, hands or other parts of the body on the blade or within the cutting path of the tool.
8. Never
allow people to walk in front of the tool during its use.
9. Never
allow people to hold/restrain the carcass.
10. Test
the tool prior to use or daily.
Depress
each trigger separately and the tool should not start.
Depress
one trigger, then pause one second and depress the other trigger and the tool should not start.
Repeat
this procedure reversing the triggers.
Depress
both triggers simultaneously and the tool should start.
With the tool running, release one trigger and the tool should stop.
Repeat
this procedure holding the
other trigger.
If the tool malfunctions, remove it from service and report or repair it immediately
.
11. Never
depress the triggers unless you want to use the tool.
12. Never
make modifications or alterations to the tool.
Report or replace any missing or illegible labels
.
Keep hands clear.