23
MC200E
Adjusting the X-sensor
1. Remove the face cover, bed cover and front
cover (do not disconnect the connectors).
2. Remove the carriage unit (refer to page 21).
3. Turn the power switch on to move the carriage to
the home position.
4. The gap between the stopper and X-carriage
guide should be 3 mm.
Loosen the setscrew and adjust the position of
the X-sensor.
5. Turn the power switch off and turn it on again to
check if the gap is 3 mm.
6. Tighten the stscrew and turn the power switch
off. Attach the carriage unit, carriage cover, front
cover, bed cover and face cover.
Stopper
3 mm
Setscrew
X-sensor
X-carriage guide