5.2   INITIAL START UP

1.  Make sure that all connections are secure and that any glued 

piping connections or joints have had sufficient time to cure.

2.  Backwash filter sand.

•  Set multiport valve to backwash.

3.  Turn on filter pump.

•  Water will discharge from waste port.
•  While pump is running, periodically check the water clarity 

through the sight glass or at the waste port.

•  Once water is visibly clear the backwash cycle is complete.
•  See “5.1 Filter Valve Functions” on page 8 for details.

4.  Turn off filter pump.
5.  Set valve to rinse.

6.  Stand clear of filter and turn on the filter pump.

•  Water will discharge from waste port.

7.  Allow filter to run for 1-2 minutes.
8.  Turn off filter pump.
9.  Set multiport valve to filter.
10. Stand clear of filter.
11.  Turn on filter pump and allow it to run normally.

•  Water will discharge to pool from return port.
•  Take the pressure reading from the pressure gage while the 

filter pump is running at its typical filtration RPM.

•  Set the pressure gage to clean using the filtration PSI as the 

“clean” mark. 

5.3  OPERATING PRESSURE

 WARNING

X

MAXIMUM OPERATING 

PRESSURE OF THE FILTER IS 

35 PSI. NEVER SUBJECT THE 

FILTER TO ANY OPERATING 

PRESSURE EXCEEDING 35 

PSI

•  Do not connect the 

system to an unregulated 

city water system or other external source of 

pressurized water producing pressures greater 

than 35 PSI.

• 

This fi lter operates under high pressure. When 

any part of the circulating system, i.e., fi lter, 

pump, valve(s), etc. is serviced, air can enter 

the system and become pressurized when the 

system is restarted.

•  Pressurized air in a system can cause product 

failure or also cause the dial valve to be blown 

off which can result in death, serious personal 

injury or property damage.

•  To minimize risk of severe injury or death, the 

fi lter and/or pump should not be subjected to 

the piping pressurization test. Local codes may 

require the pool piping system to be subjected 

to a pressure test. These requirements are 

generally not intended to apply to the pool 

equipment such as fi lters or pumps. Jandy pool 

equipment is pressure tested at the factory.

If however, this 

WARNING

 cannot be followed and 

pressure testing of the piping system must include the 

fi lter and/or pump 

BE SURE TO COMPLY WITH THE 

FOLLOWING SAFETY INSTRUCTIONS

.

•  check all clamps, bolts, lids, lock rings and 

system accessories to ensure they are properly 

installed and secured before testing.

•  RELEASE ALL AIR in the system before testing.

•  Water pressure for test must NOT EXCEED 35 

PSI

•  Water temperature for test must NOT EXCEED 

100º F (38º C).

•  Limit test to 24 hours. After test, visually check 

system to be sure it is ready for operation.

NOTICE:

 These parameters apply only to Jandy 

equipment. for non-Jandy equipment, consult the 

equipment manufacturer.

The filter is designed to operate effectively based on the 

performance curve listed below. At no time is the filter 

to be subjected to internal pressures greater than 50 psi.

1.  After initial startup run the filter pump for several minutes.
2.  Take note of the running pressure and set the “clean” indicator 

on the pressure gage dial to the filtration PSI.

3.  Check the operating pressure regularly at least once a week.

4.  Performing a backwash procedure is required once the 

pressure consistently reads 10 PSi greater than the initial 

startup pressure, 

DO NOT EXCEED 35 PSI.

5.  Follow backwash and rinse procedure. See “5.1 Filter 

Valve Functions” on page 8 and “5.2 Initial Start up” 

on page 9.

6.  If after backwashing the filter you are unable to get the 

pressure to lower sufficiently to ensure operational pressures 

below 35 PSI you will need to replace the filter sand.

Summary of Contents for SFTM22-1.5

Page 1: ...and or operation can create dangerous high pressure which can cause a catastrophic product failure and or cause the multiport valve to be blown off possibly causing death serious injury or property damage Before installing this product read and follow all warning notices and instructions that accompany this product Failure to follow warning notices and instructions may result in death serious inju...

Page 2: ...ion 5 Section 4 Initial Setup 6 4 1 Install Base 6 4 2 Install Hub and Laterals SFTM22 1 5 6 4 3 Install Hub and Laterals SFTM24 2 0 6 4 4 Fill With Sand 6 4 5 Assemble Multiport Valve 7 4 6 Install Multiport Valve 8 4 7 Plumbing 8 Section 5 Operation 8 5 1 Filter Valve Functions 8 5 2 Initial Start up 9 5 3 Operating pressure 9 5 4 Changing the filter sand 10 5 5 Winterizing 10 Section 6 Dimensio...

Page 3: ...rameters apply only to Jandy equipment For non Jandy equipment consult the equipment manufacturer To avoid electrical shock hazard which can result in serious injury or death Ensure that all electrical to the system is turned off before approaching inspecting or troubleshooting any leaking valves or plumbing that may have caused other electrical devices in the surrounding area to get wet Water dis...

Page 4: ...iece 3 11 Valve O Ring 1 12 Pressure Gauge 1 13 Drain Valve 1 14 Clamp Arm 2 Retaining Bolt 2 Capture Nut 2 15 PTFE Tape 1 1 3 2 4 5 7 8 9 10 11 12 14 13 6 15 2 2 SFTM24 2 0 Unpack and check contents If any parts are missing or damaged please call Customer Support at 1 800 822 7933 ITEM DESCRIPTION QTY 1 Multiport Valve 2 1 2 Sand Deflector 1 3 Filter Tank 1 4 Lateral Hub Assembly 1 5 Base 1 6 Unio...

Page 5: ...able of supporting the weight of the filter see Section 6 and which will accommodate the use of anchoring bolts to secure the equipment in place Check local building codes for any additional requirements If possible the equipment pad area should be Dry Well ventilated Supplied with sufficient drainage Out of direct sunlight Located away from eaves or overhangs where rain gutters are not installed ...

Page 6: ...HTEN Align tabs on lateral to slots in hub Secure wuith 1 4 turn 4 3 INSTALL HUB AND LATERALS SFTM24 2 0 1 Inspect the laterals and lateral hub assembly for damage or debris Replace or clean where needed 2 Insert the lateral hub assembly into the filter tank 3 Reach into filter tank and extend each lateral into a fully horizontal position 4 4 FILL WITH SAND 20 Silica Size Range 40 55 mm POOL FILTE...

Page 7: ...re use 4 5 ASSEMBLE MULTIPORT VALVE 1 Install pressure gauge a Remove the plug from the pressure gauge port b Install pressure gauge Screw into place until snug DO NOT OVERTIGHTEN If possible orient the gauge so that it is horizontally aligned The included Teflon tape can be used to aid in getting the appropriate orientation and fit c If possible orient the gauge so that it is right reading and pe...

Page 8: ... for 2 PVC pipe In order to reduce pressure loss 2 minimum piping is recommended SECTION 5 OPERATION This filter operates under pressure When clamped properly and operated without air in the water system this filter will operate in a safe manner All plumbing connections should be in accordance with local plumbing and building codes Do not use pipe joint compound glue or solvent on the union nut th...

Page 9: ...death serious personal injury or property damage To minimize risk of severe injury or death the filter and or pump should not be subjected to the piping pressurization test Local codes may require the pool piping system to be subjected to a pressure test These requirements are generally not intended to apply to the pool equipment such as filters or pumps Jandy pool equipment is pressure tested at ...

Page 10: ... semi fluid slurry state 6 Using steps from 4 4 Fill With Sand on page 6 replace the sand in the filter WARNING Be sure to dispose of used filter sand appropriately Used filter sand is not appropriate for human or pet contact 5 5 WINTERIZING Turn off the pump 1 Move the Multiport valve handle to Winter 2 Remove any drain plugs from the filter 3 Vent the filter by removing the pressure gauge or dis...

Page 11: ...e Multi Port Valve w Clamp Assembly 1 5 MPV 1 2 R0744700 Top Rotor Assembly 1 3 R0745100 Flange Clamp Assembly 1 4 R0745200 Drain Cap and O Ring 1 5 R0745300 Lateral Full Set 8 6 R0745400 Lateral Standpipe Assembly 1 7 R0745500 Sand Deflector 1 8 R0745800 O Ring Valve Tank 1 9 R0745000 Pressure Gauge Assembly 1 10 R0745600 Complete 1 5 Unions Kit 3 2 6 5 1 3 8 10 1 9 10 1 1 3 4 7 ...

Page 12: ... R0745700 Complete Multi Port Valve w Clamp Assembly 2 MPV 1 2 R0745100 Flange Clamp Assembly 1 3 R0745200 Drain Cap and O Ring 1 4 R0746100 Sand Deflector 1 5 R0745800 O ring Valve Tank 1 6 R0746000 Lateral Standpipe Assembly 1 7 R0745000 Pressure Gauge Assembly 1 8 R0746200 Complete 2 Unions With Adapter Kit 1 1 8 8 8 1 7 6 4 1 1 2 5 1 2 3 ...

Page 13: ...Page 13 ENGLISH Jandy Pro Series Sand Filter SFTM22 1 5 SFTM24 2 0 Installation Operation Manual NOTES ...

Page 14: ...Page 14 ENGLISH Jandy Pro Series Sand Filter SFTM22 1 5 SFTM24 2 0 Installation Operation Manual NOTES ...

Page 15: ...Page 15 ENGLISH Jandy Pro Series Sand Filter SFTM22 1 5 SFTM24 2 0 Installation Operation Manual NOTES ...

Page 16: ...enced herein are the property of their respective owners 2016 Zodiac Pool Systems Inc H0579200_REVD Zodiac Pool Systems Inc 2620 Commerce Way Vista CA 92081 1 800 822 7933 www jandy com Zodiac Pool Systems Canada Inc 2115 South Service Road West Unit 3 Oakville ON L6L 5W2 1 888 647 4004 www ZodiacPoolSystems ca ...

Reviews: