background image

Page 3 

ENGLISH

  

 

Jandy

® 

Pro Series Sand Filter SFTM22-1.5, SFTM24-2.0   

|

   Installation & Operation Manual

SECTION 1.  IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS

 WARNING

X

MAXIMUM OPERATING PRESSURE OF THE FILTER IS 35 PSI. NEVER SUBJECT THE 

FILTER TO ANY OPERATING PRESSURE EXCEEDING 35 PSI

•  Do not connect the system to an unregulated city water system or other 

external source of pressurized water producing pressures greater than 35 PSI.

• 

This fi lter operates under high pressure. When any part of the circulating 

system, i.e., fi lter, pump, valve(s), etc. is serviced, air can enter the system and 

become pressurized when the system is restarted.

•  Pressurized air in a system can cause product failure or also cause the dial 

valve to be blown off which can result in death, serious personal injury or property damage.

• 

To minimize risk of severe injury or death, the fi lter and/or pump should not be subjected to the piping 

pressurization test. Local codes may require the pool piping system to be subjected to a pressure 

test. These requirements are generally not intended to apply to the pool equipment such as fi lters or 

pumps. Jandy pool equipment is pressure tested at the factory.

If however, this 

WARNING

 cannot be followed and pressure testing of the piping system must include the fi lter and/

or pump 

BE SURE TO COMPLY WITH THE FOLLOWING SAFETY INSTRUCTIONS

.

•  Check all clamps, bolts, lids, locking devices and system accessories to ensure they are properly 

installed and secured before testing.

•  RELEASE ALL AIR in the system before testing.

•  Water pressure for test must NOT EXCEED 35 PSI

• 

Water temperature for test must NOT EXCEED 100º F (38º C).

•  Limit test to 24 hours. After test, visually check system to be sure it is ready for operation.

NOTICE:

 These parameters apply only to Jandy equipment. For non-Jandy equipment, consult the equipment 

manufacturer.
To avoid electrical shock hazard, which can result in serious injury or death:

•  Ensure that all electrical to the system is turned off before approaching, inspecting or troubleshooting 

any leaking valves or plumbing that may have caused other electrical devices in the surrounding area 

to get wet.

• 

Water discharged from an improperly positioned fi lter or valve can create an electrical hazard which 

can cause death, serious injury or property damage.

• 

Improper dial valve installation can cause product failure or also cause the fi lter dial to be blown off, 

which can result in death, serious personal injury or property damage.

•  Never attempt to adjust or remove the dial valve when the pump is running or there is pressure in the 

system. this can cause product failure or also cause the fi lter dial to be blown off, which can result in 

death, serious personal injury or property damage.

 CAUTION

•  Maintain your pressure gauge in good working order. The pressure gauge is the primary indicator of 

how the fi lter is operating.

•  Creating high vacuum levels can cause the tank vessel to crack and leak with the potential for 

property damage.

•  Be sure that all provisions for waste water disposal meet local, provincial or national codes. During 

any backwash or draining process, 100 gallons or more of water will be discharged. Do not discharge 

water where it will cause fl ooding or damage.

• 

To avoid damaging the laterals (spokes), slowly add the fi lter media until the laterals are fully covered. 

Consult Installation and Operation Manual for complete sand fi lling instructions Cracked or broken 

laterals (spokes) will cause sand to be discharged to the pool.

Attention installer:

 This manual contains important information about the installation, operation 

and safe use of this product. This information should be given to the owner/operator of this 

equipment.

SAVE THESE INSTRUCTIONS

Summary of Contents for SFTM22-1.5

Page 1: ...and or operation can create dangerous high pressure which can cause a catastrophic product failure and or cause the multiport valve to be blown off possibly causing death serious injury or property damage Before installing this product read and follow all warning notices and instructions that accompany this product Failure to follow warning notices and instructions may result in death serious inju...

Page 2: ...ion 5 Section 4 Initial Setup 6 4 1 Install Base 6 4 2 Install Hub and Laterals SFTM22 1 5 6 4 3 Install Hub and Laterals SFTM24 2 0 6 4 4 Fill With Sand 6 4 5 Assemble Multiport Valve 7 4 6 Install Multiport Valve 8 4 7 Plumbing 8 Section 5 Operation 8 5 1 Filter Valve Functions 8 5 2 Initial Start up 9 5 3 Operating pressure 9 5 4 Changing the filter sand 10 5 5 Winterizing 10 Section 6 Dimensio...

Page 3: ...rameters apply only to Jandy equipment For non Jandy equipment consult the equipment manufacturer To avoid electrical shock hazard which can result in serious injury or death Ensure that all electrical to the system is turned off before approaching inspecting or troubleshooting any leaking valves or plumbing that may have caused other electrical devices in the surrounding area to get wet Water dis...

Page 4: ...iece 3 11 Valve O Ring 1 12 Pressure Gauge 1 13 Drain Valve 1 14 Clamp Arm 2 Retaining Bolt 2 Capture Nut 2 15 PTFE Tape 1 1 3 2 4 5 7 8 9 10 11 12 14 13 6 15 2 2 SFTM24 2 0 Unpack and check contents If any parts are missing or damaged please call Customer Support at 1 800 822 7933 ITEM DESCRIPTION QTY 1 Multiport Valve 2 1 2 Sand Deflector 1 3 Filter Tank 1 4 Lateral Hub Assembly 1 5 Base 1 6 Unio...

Page 5: ...able of supporting the weight of the filter see Section 6 and which will accommodate the use of anchoring bolts to secure the equipment in place Check local building codes for any additional requirements If possible the equipment pad area should be Dry Well ventilated Supplied with sufficient drainage Out of direct sunlight Located away from eaves or overhangs where rain gutters are not installed ...

Page 6: ...HTEN Align tabs on lateral to slots in hub Secure wuith 1 4 turn 4 3 INSTALL HUB AND LATERALS SFTM24 2 0 1 Inspect the laterals and lateral hub assembly for damage or debris Replace or clean where needed 2 Insert the lateral hub assembly into the filter tank 3 Reach into filter tank and extend each lateral into a fully horizontal position 4 4 FILL WITH SAND 20 Silica Size Range 40 55 mm POOL FILTE...

Page 7: ...re use 4 5 ASSEMBLE MULTIPORT VALVE 1 Install pressure gauge a Remove the plug from the pressure gauge port b Install pressure gauge Screw into place until snug DO NOT OVERTIGHTEN If possible orient the gauge so that it is horizontally aligned The included Teflon tape can be used to aid in getting the appropriate orientation and fit c If possible orient the gauge so that it is right reading and pe...

Page 8: ... for 2 PVC pipe In order to reduce pressure loss 2 minimum piping is recommended SECTION 5 OPERATION This filter operates under pressure When clamped properly and operated without air in the water system this filter will operate in a safe manner All plumbing connections should be in accordance with local plumbing and building codes Do not use pipe joint compound glue or solvent on the union nut th...

Page 9: ...death serious personal injury or property damage To minimize risk of severe injury or death the filter and or pump should not be subjected to the piping pressurization test Local codes may require the pool piping system to be subjected to a pressure test These requirements are generally not intended to apply to the pool equipment such as filters or pumps Jandy pool equipment is pressure tested at ...

Page 10: ... semi fluid slurry state 6 Using steps from 4 4 Fill With Sand on page 6 replace the sand in the filter WARNING Be sure to dispose of used filter sand appropriately Used filter sand is not appropriate for human or pet contact 5 5 WINTERIZING Turn off the pump 1 Move the Multiport valve handle to Winter 2 Remove any drain plugs from the filter 3 Vent the filter by removing the pressure gauge or dis...

Page 11: ...e Multi Port Valve w Clamp Assembly 1 5 MPV 1 2 R0744700 Top Rotor Assembly 1 3 R0745100 Flange Clamp Assembly 1 4 R0745200 Drain Cap and O Ring 1 5 R0745300 Lateral Full Set 8 6 R0745400 Lateral Standpipe Assembly 1 7 R0745500 Sand Deflector 1 8 R0745800 O Ring Valve Tank 1 9 R0745000 Pressure Gauge Assembly 1 10 R0745600 Complete 1 5 Unions Kit 3 2 6 5 1 3 8 10 1 9 10 1 1 3 4 7 ...

Page 12: ... R0745700 Complete Multi Port Valve w Clamp Assembly 2 MPV 1 2 R0745100 Flange Clamp Assembly 1 3 R0745200 Drain Cap and O Ring 1 4 R0746100 Sand Deflector 1 5 R0745800 O ring Valve Tank 1 6 R0746000 Lateral Standpipe Assembly 1 7 R0745000 Pressure Gauge Assembly 1 8 R0746200 Complete 2 Unions With Adapter Kit 1 1 8 8 8 1 7 6 4 1 1 2 5 1 2 3 ...

Page 13: ...Page 13 ENGLISH Jandy Pro Series Sand Filter SFTM22 1 5 SFTM24 2 0 Installation Operation Manual NOTES ...

Page 14: ...Page 14 ENGLISH Jandy Pro Series Sand Filter SFTM22 1 5 SFTM24 2 0 Installation Operation Manual NOTES ...

Page 15: ...Page 15 ENGLISH Jandy Pro Series Sand Filter SFTM22 1 5 SFTM24 2 0 Installation Operation Manual NOTES ...

Page 16: ...enced herein are the property of their respective owners 2016 Zodiac Pool Systems Inc H0579200_REVD Zodiac Pool Systems Inc 2620 Commerce Way Vista CA 92081 1 800 822 7933 www jandy com Zodiac Pool Systems Canada Inc 2115 South Service Road West Unit 3 Oakville ON L6L 5W2 1 888 647 4004 www ZodiacPoolSystems ca ...

Reviews: