Thank you for purchasing Jandy™ pool and spa products. Zodiac Pool Systems Canada, Inc. (manufacturer of Jandy products) warrants all parts to be free from 
manufacturing defects in materials and workmanship for a period of one year from the date of retail purchase. This warranty is limited to the first retail purchaser, is 
not transferable, and does not apply to products that have been moved from their original installation sites. The liability of Zodiac Pool Systems Canada, Inc. shall not 
exceed the repair or replacement of defective parts and does not include any costs for labor to remove and reinstall the defective part, transportation to or from the 
factory, and any other materials required to make the repair. This warranty does not cover failures or malfunctions resulting from the following:

1. Failure to properly install, operate or maintain the product(s) in accordance with our published Installation, Operation and Maintenance Manuals provided with the 
product(s).
2. The workmanship of any installer of the product(s).
3. Not maintaining a proper chemical balance in your pool and/or spa [pH level between 7.2 and 7.8, Total Alkalinity (TA) between 80 to 120 ppm, Total Dissolved 
Solids (TDS) less than 2000 not including salt ppm].
4. Abuse, alteration, accident, fire, flood, lightning, rodents, insects, negligence or acts of God.
5. Scaling, freezing, or other conditions causing inadequate water circulation.
6. Operating the product(s) at water flow rates outside the published minimum and maximum specifications.
7. Use of non-factory authorized parts or accessories in conjunction with the product(s).
8. Chemical contamination of combustion air or improper use of sanitizing chemicals, such as introducing sanitizing chemicals upstream of the heater and cleaner hose 
or through the skimmer.
9. Overheating; incorrect wire runs; improper electrical supply; collateral damage caused by failure of O-Rings, DE grids, or cartridge elements; or damage caused by 
running the pump with insufficient quantities of water.

LIMITATION OF LIABILITY:

This is the only warranty given by Zodiac Pool Systems Canada, Inc. No one is authorized to make any other warranties on behalf of Zodiac Pool Systems Canada, Inc. 

THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF FITNESS 
FOR A PARTICULAR PURPOSE AND MERCHANTABILITY. ZODIAC POOL SYSTEMS CANADA, INC. EXPRESSLY DISCLAIMS AND EXCLUDES ANY LIABILITY FOR 
CONSEQUENTIAL, INCIDENTAL, INDIRECT OR PUNITIVE DAMAGES FOR BREACH OF ANY EXPRESSED OR IMPLIED WARRANTY.

 This warranty gives you specific 

legal rights. You may also have other rights which vary by state or province.

WARRANTY CLAIMS:

For prompt warranty consideration, contact your dealer and provide the following information: proof of purchase, model number, serial number and date of installation. 
The installer will contact the factory for instructions regarding the claim and to determine the location of the nearest designated service center. If the dealer is not 
available, you can locate a service center in your area by visiting www.jandy.com or by calling our technical support department at (888) 647-4004. All returned 
parts must have a Returned Material Authorization number to be evaluated under the terms of this warranty.

Summary of Contents for SFTM Series

Page 1: ...company this filter Failure to follow warning notices and instructions may result in property damage serious injury or death POUR VOTRE S CURIT Ce produit doit tre install et entretenu par un technici...

Page 2: ...sure testing of the piping system must include the filter and or pump BE SURE TO COMPLY WITH THE FOLLOWING SAFETY INSTRUCTIONS Check all clamps bolts lids lock rings and system accessories to ensure t...

Page 3: ...s for wastewater disposal meet local provincial or national codes During any backwashing or draining process 100 gallons or more of pool water will be discharged Do not discharge water where it will c...

Page 4: ...bed after backwashing and carries any remaining loose dirt to the waste 7 TEST prevents only backflow of water from pool during pump maintenance if filter is below water level FILTER SAND The outstand...

Page 5: ...ify a primer must be used Caution We recommend that you consider climatic conditions when applying adhesives Certain atmospheric situations such as high moisture content make the adhesive action of ce...

Page 6: ...mp Take the cover off the hair and lint strainer and check that most of the water drains from the pump and strainer Store the pump and motor indoors or protect them from the elements and extreme tempe...

Page 7: ...Bolts Pressure Gauge 0 60 PSI R0492000 3 Drain Nozzle Assembly Drain Nozzle Drain Nozzle Retainer Drain Cap w Gasket R0492100 4 SFTM22 Lateral and Standpipe Assembly 22 Lateral Kit Snap Fit 8 per bag...

Page 8: ...authorized parts or accessories in conjunction with the product s 8 Chemical contamination of combustion air or improper use of sanitizing chemicals such as introducing sanitizing chemicals upstream o...

Page 9: ...LA PRESSION D UTILISATION MAXIMALE DU FILTREUR EST DE 35 LB PO2 NE SOUMETTEZ JAMAIS LE FILTREUR UNE PRESSION SUP RIEURE 35 LB PO2 Ce filtreur fonctionne sous grande pression Lorsque n importe quelle p...

Page 10: ...s r glements locaux provinciaux ou nationaux Au cours du cycle de lavage ou du processus d assainissement 100 gallons ou plus d eau de piscine seront d vers s N envoyez pas l eau l o cela pourrait pro...

Page 11: ...CKWASH remous entra ne une circulation vers le haut au travers du lit filtrant cet coulement enl ve la salet du sable et la d verse dans l gout 3 Le rep re DRAIN drainage permet de pomper l eau de la...

Page 12: ...an adh sif TeflonMD ou l quivalent pour raccorder les joints filet s D autres adh sifs pour tuyaux pourraient endommager le filetage des joints Nous ne recommandons pas l usage de silicone ou de compo...

Page 13: ...faire effectuer les r parations sur votre syst me durant la p riode creuse lorsqu un bon service est plus facile obtenir n attendez pas la prochaine saison Si le moteur lectrique doit tre r par l appo...

Page 14: ...r t de la buse du drain Bouchon de drain avec joint d tanch it R0492100 4 Assemblage conduites secondaires et r servoir cylindrique SFTM22 Trousse de conduites secondaires raccord pression 22 po paque...

Page 15: ...ique de l air de combustion ou une mauvaise utilisation des agents chimiques de d sinfection tels que l introductions des agents chimiques de d sinfection en amont du r chauffeur et le tuyau de nettoy...

Page 16: ...ZODIAC POOL SYSTEMS CANADA INC 2115 South Service Road West Unit 3 Oakville Ontario Canada L6L 5W2 Tel 1 888 647 4004 Fax 905 825 5780...

Reviews: