Page 18
Figure 13. Cell Installation
O-Ring
Seal
DC Cord Plug is Connected
to Terminal Studs
PVC Union
2" PVC Union
and 2" Nut
2" x 2" x 1½"
PVC TEE
Figure 14. Pipe Cutout
PVC Unions and 2" Nuts
For a 2" pipe, the cutout is 13
1
/
8
" with the full
unions, without the Tee.
For a 50 mm pipe, the cutout is 337 mm with the
full unions, without the Tee.
NOTE Total length of the electrolytic cell with the
full unions is 15
5
/
8
".
2" x 2" x 1½"
PVC Tee
For a 2" pipe, the cutout is 2¼"
for the Tee.
For a 50 mm pipe, the cutout is
77 mm for the Tee.
NOTE Total length of the PVC
Tee is 4¾".
Figure 12.
Flow/Temp/Salinity Sensor
Flow Sensor Face
Must Be
Clean
Connector
Sensor
2" x 2" x 1-1/2"
PVC TEE
From Pump
Teflon
Tape
Cell
Detail A
Detail B
Detail C
Preferred
Not Preferred
Hazardous
Sometimes
Not Covered
Flow Sensor Face
Must Be
Clean
i
/ Sal nity
Flow
/ Temp
2" PVC Union
WARNING
Do not operate the electrolytic cell without water circulation. A buildup of flammable gases will result
in hazardous conditions.