background image

Jandy

® 

Infinite WaterColors

™ 

Nicheless LED Light  |  Owner’s Manual

Jandy

® 

Infinite WaterColors

™ 

Nicheless LED Light  |  Owner’s Manual

ENGLISH  

 

Page 9

2.  Snake the electric cord through the conduit outlet of the wall fitting, 

into the conduit and up to the location of the pool transformer. Cut the 

cord 18”-24” beyond the length needed to reach the transformer to 

allow for a service loop. Pull the fixture snug to the wall fitting.

3.  Remove protective cover after construction (including plastering for 

gunite pools) is complete. Do not plaster the pool with the construction 

cover removed.

4.  Install cosmetic cover if desired.

5.  Apply teflon silicone lube to threads to assist with threading.

NOTE: 

When using a 1 1/2” MIP fitting on the back of a SP-1022 or 

 

SP-1408 Wall Fitting, the interior of the Spears and Dura MIP are too small 

for use with the Jandy

®

 Infinite WaterColors Nicheless LED  Lights.

 

6.  Using the included installation tool,  

thread the light into the wall fitting 

 

until it is snug. The light face must  

be completely flush with the return 

 

fitting. Please provide the pool 

 

owner with a minimum of 1 key  

upon job completion.

NOTE: Service 

Loop not applicable 

for Junction Box 

Installations.

Vertical Installation

Infinite WaterColors LED Light Controller, 

see table 3.2 for more details

The light face must be completely 

snug with the light fitting without 

any protrusion from the light fixture.

Conduit to 14VAC Magnetic Transformer

14VAC Magnetic Transformer

The light must be installed with the 

light face completely snug with the 

light fitting, without any protrusion 

from the light fixture, and in 

accordance with applicable local 

codes and AHJ (Authority Having 

Jurisdiction) requirements. 

Figure 3. 

Standard installation with 1.5” pool wall fitting

Summary of Contents for Infinite WaterColors IWC15W100

Page 1: ...d and follow all warning notices and instructions that accompany this product Failure to follow warning notices and instructions may result in property damage personal injury or death Improper install...

Page 2: ...ng the Light Fixture 8 3 3 Wet Area Installations 9 Section 4 Controller Wiring Options 10 4 1 Wiring to an AquaLink RS Control System 10 4 2 Wire Gauge and Length 11 4 3 Fourteen 14 Volt Installation...

Page 3: ...ned to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in ac...

Page 4: ...or property damage Visit www zodiacpoolsystems com for additional free copies of these instructions or call Zodiac Technical Support at 800 822 7933 U S or 888 647 4004 Canada DANGER RISK OF ELECTRICA...

Page 5: ...order to prevent risk of property damage and or injury no service should be attempted to the light in the event of a malfunction The complete light assembly must be replaced WARNING RISK OF ELECTRICA...

Page 6: ...st be installed by a licensed or certified electrician or a qualified pool serviceman in accordance with the National Electrical Code Canadian Electrical Code in Canada and all applicable local codes...

Page 7: ...roller is suitable for direct conduit connection to lights and must be located at least 8 inches above water level at least four 4 inches above ground level and at least 48 inches 4 feet from the edge...

Page 8: ...m possible water line top of copping Figure 1 Jandy LED Light Installation with Standard 1 5 Plastic Fitting Use the chart below to determine the appropriate pipe length for your installation WATTS MI...

Page 9: ...are too small for use with the Jandy Infinite WaterColors Nicheless LED Lights 6 Using the included installation tool thread the light into the wall fitting until it is snug The light face must be co...

Page 10: ...transformer The maximum run of service between transformer and lights should not exceed 200ft in length inclusive of the use of a J Box or not To the extent allowed by local installation codes in effe...

Page 11: ...hts to the LED Light Controller Refer to the Infinite WaterColors LED Light Controller manual for connecting to the AquaLink RS automation system 1 Knock out an opening in the right compartment 2 Run...

Page 12: ...Jandy Lights to any dimming circuitry DO NOT CONNECT TWO OR MORE POWER SUPPLIES IN PARALLEL CAUTION To prevent risk of fire which could result in property damage and to ensure optimum performance do n...

Page 13: ...e and follow further instructions in the app NOTE When exiting the Light Zone Setup page the lights will turn off NOTE Lights have to be assigned to a zone in order to rename the zone 5 1 2 Name Light...

Page 14: ...ction 6 OneTouch Setup 6 1 Light Setup 6 1 1 Assign Lights 1 Choose menu on the OneTouch display screen and press select 2 From the menu screen go to System Setup IWC Lights 3 Select zone set up 4 Fro...

Page 15: ...4 or more above or below the light depending on the pool s other winterization needs Consult a Local Swimming Pool Professional for proper winterization At NO TIME should there be water removed from...

Page 16: ...warrantable One or more lights are dim blinking or not working Poor connection or improper wire gauge Separate each light and independently wire 14VAC to a single light only Repeat this process for e...

Reviews: