background image

Page 10

ENGLISH 

  

Jandy

® 

Infinite WaterColors

™ 

Nicheless LED Light  |  Owner’s Manual

3.3  Wet Area Installations

For wet area lighting within 10 feet (3M) of a pool or spa, the luminaire 

shall be installed in areas not subject to incidental contact from people, pets, 

vehicles, and foot traffic, except when the luminaire is adequately guarded. 

Section 4.  Controller Wiring Options

The Jandy Infinite WaterColors Nicheless LED Light is designed 

to be powered and operated with the Jandy Infinite WaterColors 

LED Light Controller, the lights will not operate when powered 

from an alternate transformer. Follow all installation and operating 

instructions that accompany this product, as well as the Jandy 

Infinite WaterColors LED Light Controller (Model: IWCLC300W). 

NOTE:

 Always consider the cable length when calculating the input 

voltage at the transformer. The maximum run of service between 

transformer and lights should not exceed 200ft. in length, inclusive 

of the use of a J Box or not.

To the extent allowed by local installation codes in effect in the installation 

jurisdiction and capacity of the electrical equipment, multiple Jandy lights 

may be controlled with a Infinite WaterColors LED Light Controller.

4.1  Wiring to an AquaLink

®

 RS Control System

 WARNING

RISK OF ELECTRICAL SHOCK OR ELECTROCUTION, 

which could result in serious injury or death. 

A Ground 

Fault Circuit Interrupter (GFCI, in Canada: Class A type) for 120 

Volt transformers should be used if required by the transformer 

manufacturer or if required by the local applicable code and/or 

Authority Having Jurisdiction (AHJ). When a GFCI is used, the 

conductors on the load side of the GFCI circuit shall not occupy 

conduit, boxes, or enclosures containing other conductors unless the 

additional conductors are also protected by a GFCI. Test the GFCI 

on a routine basis. Refer to local codes for complete details.

Summary of Contents for Infinite WaterColors IWC15W100

Page 1: ...d and follow all warning notices and instructions that accompany this product Failure to follow warning notices and instructions may result in property damage personal injury or death Improper install...

Page 2: ...ng the Light Fixture 8 3 3 Wet Area Installations 9 Section 4 Controller Wiring Options 10 4 1 Wiring to an AquaLink RS Control System 10 4 2 Wire Gauge and Length 11 4 3 Fourteen 14 Volt Installation...

Page 3: ...ned to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in ac...

Page 4: ...or property damage Visit www zodiacpoolsystems com for additional free copies of these instructions or call Zodiac Technical Support at 800 822 7933 U S or 888 647 4004 Canada DANGER RISK OF ELECTRICA...

Page 5: ...order to prevent risk of property damage and or injury no service should be attempted to the light in the event of a malfunction The complete light assembly must be replaced WARNING RISK OF ELECTRICA...

Page 6: ...st be installed by a licensed or certified electrician or a qualified pool serviceman in accordance with the National Electrical Code Canadian Electrical Code in Canada and all applicable local codes...

Page 7: ...roller is suitable for direct conduit connection to lights and must be located at least 8 inches above water level at least four 4 inches above ground level and at least 48 inches 4 feet from the edge...

Page 8: ...m possible water line top of copping Figure 1 Jandy LED Light Installation with Standard 1 5 Plastic Fitting Use the chart below to determine the appropriate pipe length for your installation WATTS MI...

Page 9: ...are too small for use with the Jandy Infinite WaterColors Nicheless LED Lights 6 Using the included installation tool thread the light into the wall fitting until it is snug The light face must be co...

Page 10: ...transformer The maximum run of service between transformer and lights should not exceed 200ft in length inclusive of the use of a J Box or not To the extent allowed by local installation codes in effe...

Page 11: ...hts to the LED Light Controller Refer to the Infinite WaterColors LED Light Controller manual for connecting to the AquaLink RS automation system 1 Knock out an opening in the right compartment 2 Run...

Page 12: ...Jandy Lights to any dimming circuitry DO NOT CONNECT TWO OR MORE POWER SUPPLIES IN PARALLEL CAUTION To prevent risk of fire which could result in property damage and to ensure optimum performance do n...

Page 13: ...e and follow further instructions in the app NOTE When exiting the Light Zone Setup page the lights will turn off NOTE Lights have to be assigned to a zone in order to rename the zone 5 1 2 Name Light...

Page 14: ...ction 6 OneTouch Setup 6 1 Light Setup 6 1 1 Assign Lights 1 Choose menu on the OneTouch display screen and press select 2 From the menu screen go to System Setup IWC Lights 3 Select zone set up 4 Fro...

Page 15: ...4 or more above or below the light depending on the pool s other winterization needs Consult a Local Swimming Pool Professional for proper winterization At NO TIME should there be water removed from...

Page 16: ...warrantable One or more lights are dim blinking or not working Poor connection or improper wire gauge Separate each light and independently wire 14VAC to a single light only Repeat this process for e...

Reviews: