Page 9
ENGLISH
Jandy
®
Versa-Plumb
®
Cartridge Pool Filters
|
Installation & Operation Manual
LXi Heater
CV Filter
SHP
Pump
Sweep Elbow
P/N SEAQL1001
Sweep Elbow
P/N SEFL1002
7½”
Minimum
Figure 7. Sweep Elbow
Note: Do not
overtighten.
Figure 8. LXi
™
Heater, CV Filter and SHP Pump Sweep Elbow Installation
NOTE
The SHP pump shown in Figure 8 is for reference only.
The Jandy Pro sweep elbow also works with the MHP
and PHP series pumps.
NOTE
Be sure to use 2" or 2½" schedule 40 PVC pipe.
c.
Clean the cut ends of the pipe and both ends of
the sweep elbow(s) with an appropriate NSF
®
approved All Purpose cleaner/primer. Glue the
sweep elbow(s) onto the cut pipe ends using
an appropriate All Purpose NSF approved
adhesive/glue.
NOTE
Zodiac recommends Weld-On 724 PVC to CPVC
Cement to glue Schedule 40 PVC.
d.
After the glue is cured, close the pressure
relief valve on top of the filter, start the system
and check for proper water flow.
6.
Make all plumbing connections in accordance
with local plumbing and building codes. Filter
connections are provided with an o-ring seal. To
avoid damage to the o-rings, use only a silicone
base lubricant on the o-rings.
Do not use pipe
joint compound, glue or solvent on inlet/
outlet union coupling nuts.
7.
Keep piping tight and free of leaks. Pump
suction line leaks may cause air to be entrapped
in filter tank or loss of prime at the pump. Pump
discharge line leaks may show up as dampness or
jets of water.
8.
Support the inlet/outlet pipes independently to
prevent any undue strains on the filter valve.
9.
Connect the pipes using the unions supplied with
the filter.
Do not use Teflon tape or pipe dope
on any unions.
Assemble the unions dry and
hand tighten. See Figure 6.
WARNING
Follow all filter manufacturer’s
instructions.
NEVER
attempt to
assemble, disassemble or adjust the
filter when there is pressurized air in
the system. Starting the pump while
there is any pressurized air in the
system can cause product failure or
also cause the filter lid to be blown
off, which can cause death, serious
personal injury or property damage.
a.
Switch off the circuit breaker to the equipment
and open the air relief valve on top of the filter
(leave it open during this procedure).
NOTE
If the filter is below pool level, close the suction and
return line valves to isolate the filtration system.
Remove the drain plug from the filter. Let the water
drain from the filter.
b.
Be sure there is a minimum distance of
7½ inches between the center of the pump
outlet port and the filter inlet bulkhead to
accommodate the sweep elbow(s). See Figure
8 for recommended installation configuration.