background image

Page 8

Section 3. Installation Instructions Model APURE700 and APURE1400

3.1 Materials 

and 

Tools

NOTE

  Salt not included. See pages 17 - 20.

Installation Materials Furnished

Tools Needed for Installation

(1 ea.) 

Electrolytic Cell with 2”-2.5” Universal Unions

(1 ea.) 

Port Plug with 16 ft (4.88 m) Sensor and O-Ring

(3 ea.) 

Universal Union Nut

(1 ea.) 

16 ft (4.88 m) DC Power Cord

(1 ea.) 

Power Supply/Control Center

(4 ea.) 

Anchors and Screws

(2 ea.) 

Wire Nuts

(1 ea.) 

Owner’s Manual - Warranty Information

Tape Measure

Phillips & Flathead Screwdrivers

Pliers

Hacksaw

Voltmeter to determine line voltage of AC wiring to power supply

Electric Drill Motor and 1/4 “ masonry drill bit for mounting power supply on 
block or stucco wall

An NSF

®

 approved All Purpose Cleaner Primer

An NSF

®

 approved All Purpose Cement (such as Weld-On 794, 793)

3.2 Plumbing 

Confi gurations

  WARNING

When using electrical products, basic precautions should always be followed, including the following:

•  DANGER: RISK OF ELECTRIC SHOCK WHICH CAN RESULT IN SERIOUS INJURY OR DEATH. 

Before attempting installation or service, ensure that all power to the device is disconnected/turned 
off at the circuit breaker. Connect only to a circuit protected by a ground-fault circuit-interrupter 
(GFCI).

•  Grounding is required. The unit should be installed by a qualifi ed service representative and

should be properly grounded. (See Earth Bonding, page 11).

•  Install to permit access for servicing.

•  Read Cautions and Important Instructions on page 4.  

Before attempting any electrical wiring, be 

sure to read and follow Safety Instructions.  Wiring should only be attempted by a qualifi ed 
professional.

Summary of Contents for AquaPure APURE700

Page 1: ...Pending Installation and Operation Manual WARNING FOR YOUR SAFETY This product must be installed and serviced by a professional pool spa service technician The procedures in this manual must be follo...

Page 2: ......

Page 3: ...6 Chlorine Testing 18 4 7 Salt NaCl sodium chloride 18 4 7 1 When to Add Salt 18 4 7 2 What Type of Salt to Use 18 4 7 3 How Much Salt to Use 19 4 7 4 How to Add Salt to the Pool 19 Section 5 Operati...

Page 4: ...Such a GFCI should be provided by the installer and should be tested on a routine basis To test the GFCI push the test button The GFCI should interrupt power Push the reset button Power should be res...

Page 5: ...t can withstand splash out of pool water containing chlorine and or salt and other water purification chemicals All metal components used in and around a pool should be of a high grade quality stainle...

Page 6: ...ell The AquaPure electrolytic cell contains bipolar electrodes which perform the electrolysis and produce chlorine when energized with DC current Chlorine is generated as pool water containing salt pa...

Page 7: ...Control ORP External Control Connector AquaLink RS485 Connector External Control ORP External Control Connector AquaLink RS485 Connector CAUTION Factory wired for 240 VAC service If available electric...

Page 8: ...F approved All Purpose Cleaner Primer An NSF approved All Purpose Cement such as Weld On 794 793 3 2 Plumbing Configurations WARNING When using electrical products basic precautions should always be f...

Page 9: ...or Orientation with Flow Direction 3 2 1 Recommended Cell and Sensor Orientation Shown below are four different cell and sensor orientations The third port on the cell is designed for installation of...

Page 10: ...g Figure 3 shows cell and sensor configuration with flow direction Figures 4 and 5 illustrates the recommended plumbing configurations which result in the most reliable operation Note The AquaPure is...

Page 11: ...on the backplate on the mounting surface Mark screw centers and drill four inch 6 35 mm holes spaced 10 3 8 inches 264 mm on the horizontal center and 6 3 8 inches 162 mm on the vertical center Instal...

Page 12: ...fety and safety of equipment 3 4 Earth Bonding Grounding A solid copper 8 AWG 8 4 mm2 wire is recommended for connecting the control center to a Permanent Earth Ground connection that is acceptable to...

Page 13: ...ngth of the electrolytic cell with the full unions is 16 Sensor Port Plug and Nut 2 pvc 2 pvc Figure 8 Flow Temp Salinity Sensor Cell Connector Flow Temp Salinity Sensor or Sometimes Not Covered Tempe...

Page 14: ...er enclosure 11 Prior to reattaching front cover check the wiring Be sure the Flow Temp Salinity Sensor is plugged in The DC cord should be plugged in Also check the AC wiring CAUTION Do not overtight...

Page 15: ...the AquaPure from the red 4 pin terminal bar to the AquaLink RS red 4 pin terminal bar see Figure 12 NOTE The screw terminals are removable to aid in installation IMPORTANT Attach the AquaPure wires t...

Page 16: ...5 m3 capacity 4 2 Determining Pool Size Gallons of Water in Your Pool Rectangular Pools Average length feet x average width feet x average depth feet x 7 5 gallon capacity Circular Pools Diameter feet...

Page 17: ...Metals some metals can cause loss of chlorine Also metals can stain your pool Have your local pool professional check for metals and recommend methods of removal 4 Chloramines should not be present i...

Page 18: ...Compare the samples A higher level should be found at the pool return line The higher level at the pool return line indicates the AquaPure is producing chlorine 1 At the pool return line 2 18 inches...

Page 19: ...alt be inadvertently added to the pool see Section 7 Troubleshooting NOTE To convert gpl grams per liter of a salt solution to PPM Parts Per Million of a salt solution multiply by 1000 i e 3 0 gpl sal...

Page 20: ...and splash out of pool water containing chlorine and or salt and other water purification chemicals All metal components used in and around a pool should be of a high grade quality stainless steel Car...

Page 21: ...lbs 132 kg 290 lbs 145 kg 320 lbs 159 kg 350 lbs 172 kg 380 lbs 186 kg 410 lbs 197 kg 435 lbs 210 kg 464 lbs 224 kg 493 lbs 237 kg 522 lbs 250 kg 551 lbs 263 kg 580 lbs 1 50 g l 57 kg 125 lbs 68 kg 1...

Page 22: ...Salt Concentration Before Addition Salt Addition Required per 1000 gallon pool capacity 0 0 gpl 25 6 lbs 11 6 kg 1 5 gpl 12 8 lbs 5 8 kg 0 3 gpl 23 5 lbs 10 7 kg 1 8 gpl 10 7 lbs 4 8 kg 0 5 gpl 21 4...

Page 23: ...tment Pressing the arrow button A or arrow button B will change the CHLORINE PRODUCTION in 5 increments Generally adjustments to production should be made in 10 increments Salinity Press the Salinity...

Page 24: ...PRODUCTION in 5 increments Generally adjustments to production should be made in 10 increments AquaLink RS Power Center Press the Mode Select button to put the AquaLink RS in the Time Out mode Press...

Page 25: ...rine Salinity Salinity is displayed along with the gpl grams per liter indicator when the Salinity button is depressed If a reading of HH appears the salinity is above 4 5 to 6 5 gpl depending on pool...

Page 26: ...the desired setting press the Salinity button to confirm the new beeper volume setting The change will be stored in permanent memory If you do not wish to keep the change wait 5 seconds and the chang...

Page 27: ...ne production 5 4 Startup 5 4 1 Shocking Shocking Super Chlorination is recommended before pool startup Start out with good pool water from the beginning The AquaPure will build up a sufficient level...

Page 28: ...your manual in a safe place Increase Chlorine Production before party time and return to normal afterwards Increase Chlorine Production when temperature goes up Increase Chlorine Production when numb...

Page 29: ...of 3 0 3 5 gpl for optimum performance of the AquaPure If additional salt is required follow the procedures and charts described on pages 17 through 20 If salt level does not rise after 24 hours see...

Page 30: ...oes not need to be cleaned STOP THE CLEANING PROCESS go on to next step e Otherwise allow the cell to remain in the solution until the foaming has stopped However do not leave in acid for more than 1...

Page 31: ...eeze damage to the Cell and Flow Temp Salinity Sensor by running pump continuously or winterize pool by draining water from pump filter and all intake and return lines Remove the cell clean and store...

Page 32: ...llow to run for 24 hours Recheck If still too low Super Chlorinate with outside source Take pool water sample to Pool Professional See pages 22 and 25 Low Less than 2 5 gpl salt level in pool water Te...

Page 33: ...ter cleaning procedures Obstruction in the AquaPure cell Remove cell for inspection Follow cleaning procedures See page 27 Flow Temp Salinity Sensor not installed properly Ensure that the Flow Temp Sa...

Page 34: ...circuit board Cycle Power Water temperature too low Winterize your pool See page 29 All the above have been checked and indicator light is still on Contact your authorized service representative Prob...

Page 35: ...rvice representative 171 Possible Backboard service condition Contact an authorized service representative 172 Flow Sensor service condition or flow sensor is unplugged Contact an authorized service r...

Page 36: ...the digital display 1 Press and hold button D for 15 seconds third beep 2 Within 5 seconds momentarily press C to enter the Fahrenheit Celsius change mode 3 To toggle between Celsius and Fahrenheit pr...

Page 37: ...URE700 Control Box Cover APURE1400 1 1 3 R0404300 Control Box Decal APURE Top 1 4 R0404400 Control Box Decal APURE Bottom 1 5 R0403900 PCB Front LED All Models Rev B10038 01 1 6 T1005 Transformer 50 6...

Page 38: ...Screw 6 X 1 2 3 6 1 2 14 R0452300 R0452400 7 Blade Cell 3 Port Cell 14 Blade Cell 3 Port Cell Includes Cell Assy APure O Ring 2 231 DC 16Ft Power Cord Blk 1 3 1 16 R0452500 Port Sensor 3 Port Cell inc...

Page 39: ...2 1 6 R0403800 Flow Sensor w 16 Cable 1 9 4 2 Port Electrolytic 1 Cell and Sensor Replacement Parts ABS White Unions Dwg Kit Description Qty 1 R0403400 R0403600 2 Port Cell PURE700 w 16 DC Cable 2 Por...

Page 40: ...mum and maximum specifications 7 Use of non factory authorized parts or accessories in conjunction with the product s 8 Chemical contamination of combustion air or improper use of sanitizing chemicals...