Page 24
Chlorine Production Rate
(more or less) Adjustment
with AquaLink RS Online
The AquaLink RS Control System must be set to Service Mode before
you can change the chlorine production levels from the AquaPure
Service Panel.
AquaLink RS Power Center
Press the Mode Select button to move the AquaLink RS from Auto
Mode into Service Mode. The indicator light located next to the Service
will turn ON.
Press the Valve Select button to choose either Pool Mode to change pool
chlorine production, or Spa Mode to change spa chlorine production.
Press the Filter Pump button to turn on the pump and apply power to the
AquaPure system.
AquaPure Service Panel
Press the arrow button
A
or arrow button
B
to change the
CHLORINE
PRODUCTION
in 5% increments. Generally, adjustments to production
should be made in 10% increments.
AquaLink RS Power Center
Press the Mode Select button to put the AquaLink RS in the Time Out
mode.
Press the Mode Select button again to place it back into Auto mode.
NOTE
The Power Center must be in pool mode to change the AquaPure pool setting; it must be in spa mode to
change the AquaPure spa setting, use the valve select button to switch between the two modes. System
must be cycled through SERVICE, TIME OUT, then back to AUTO to accept the Pool Setting versus the Spa
Setting.
NOTE
When a pool pump timer is used to limit chlorinator run time, the 24 hours will only count down when the
chlorinator is on.
Temperature
Press
the
Temperature
button
D
to check the pool water temperature.
Temperature measurements can be displayed in either Fahrenheit or
Celsius. For more information, see Section 8,
Temperature Conversion
.
Summary of Contents for AquaPure APURE700
Page 2: ......