![Jandy AquaPure APURE700 Installation And Operation Manual Download Page 10](http://html1.mh-extra.com/html/jandy/aquapure-apure700/aquapure-apure700_installation-and-operation-manual_3337072010.webp)
Page 10
Figure 5.
Alternate Plumbing Confi guration for Pool or Dual Equipment Systems
Spa
Bypass for
Spillover
Pool
Cell
Heater
Spa
JANDY
Sensor
AquaLink RS
Control
System
Heater
AquaPure/
Clormatic
Figure 4.
Recommended Plumbing Confi guration for Pool/Spa Combination Systems
3.2.2
Recommended Plumbing Confi guration
The preferred installation is that the Cell and Sensors are plumbed in the return line to the pool after
(downstream of) all the pool equipment (
fi
lter, heater, solar, etc.). The Cell and Sensor
fi
tting are designed
to be plumbed into 2” PVC pipe. Adapters can be used for systems with 1½” plumbing. Figure 3 shows
cell and sensor con
fi
guration with
fl
ow direction. Figures 4 and 5 illustrates the recommended plumbing
con
fi
gurations, which result in the most reliable operation.
Note
The AquaPure is powered from the LOAD SIDE of the pool circulation pump relay or the time clock. This
ensures that the Cell only operates when the pool pump is ON. The Flow Sensor serves as a protection
device to ensure there is suffi cient fl ow for the Cell to operate.
Note
The AquaPure is powered from the LOAD SIDE of the pool circulation pump relay or the time clock. This
ensures that the Cell only operates when the pool pump is ON. The Flow Sensor serves as a protection
device to ensure there is suffi cient fl ow for the Cell to operate.
Pool
Return
Cell
Sensor
AquaLink RS
Control
System
Heater
AquaPure/
ClorMatic
Summary of Contents for AquaPure APURE700