Page 32
7.3.10 Delay On Make
1.
Make sure the control is in the
OFF
mode.
2.
To enter the Service Setup mode, press and hold
the
MENU, POOL
and
SPA
button for 5 seconds.
NOTE
The display will revert back to
OFF
after one
minute since the last key press.
3.
This feature determines the amount of time the
heat pump waits before turning on the compressor.
To select
DELAY ON MAKE
, use the
Up
or
Down
button to scroll through to display
DELAY ON
MAKE
. Press the
MENU
button. The
5 MINS
(default mode) appears, use the
Up
or
Down
button to scroll to display the desired amount of
time, press the
MENU
button to select
.
The remaining time is displayed while counting
down. Press
POOL
or
SPA
to exit the Service
Setup mode.
7.3.11 Last
Fault
1.
Make sure the control is in the
OFF
mode.
2.
To enter the Service Setup mode, press and hold
the
MENU, POOL
and
SPA
button for 5 seconds.
NOTE
The display will revert back to
OFF
after one
minute since the last key press.
3.
This feature shows on the top row the most-recent-
fault message and on the bottom row the second-
to the-last-fault message. The most-recent-fault
message and the second-to the-last-fault message
can be the same fault message if the same fault
occured consecutively.
NOTE
If there is no entry for the most-recent-fault
message and/or the second-to-the-last fault
message, the display will show *-------------*
on the corresponding row.
4.
To select Last Fault, use the
Up
or
Down
button to
scroll through to display
LAST FAULT
. Press the
MENU
button.
NOTE
The fault messages are stored in non-volatile
memory, which remain even with no power.
Once the control exits the screen that display
the stored fault messages, the control will
automatically clear the fault messages from the
non-volatile memory.