19
19. Mount the ball valve to the mount plate to rear driver’s side of applicator using (2)1/2” x 1-3/4” hex bolts and
(2) 1/2” centerlock hex nuts. A wire hangs on the cap of the valve. Before fastening the bolts with the nuts,
loop one eyelet of the wires over the bolt between the plate and the frame (as shown below).
20. Connect tank shut off valve to fill valve with 2” x 36” hose (JM0040215) for 5010 applicators and 3” x 38” hose
(JM0040216) for 5016 applicators. Connect tank shut off valve to the pump using 2” x 32” hose (JM0040224).
Tighten all four clamps (JM0035247).
Tank