Section H
Motor & Pump Assembly & Installation
Section H
IN
OUT
VHPP13
VHPP30
IN
OUT
VHPP41
VHPP57 (
shown
)
VHPP137
Installing the Pump Dipstick/Breather Valve
On the top of the pump will be a red cap, remove the red cap, insert dipstick/breather valve, and secure by hand turning until snug.
5
OIL
Red
Cap
7
Connecting Power to the Motor
• Install manual disconnect switch inside building adjacent to motor.
• Route wire to motor with drip loop and secure. Drip loop will drain accumulated moisture away from the motor.
• Configure internal wires to match supply voltage and wire according to motor nameplate.
IS275-17L
J&D Manufacturing • 6200 Hwy 12 • Eau Claire, WI 54701 • 1-800-998-2398 • www.jdmfg.com
Section H - Page 3/3
Attach Motor Pump Assembly to Motor Pump Shelf
Align the motor foot mount with a matching set of pre-drilled mounting holes in the shelf top. Using one of the below matched tool and hardware combinations
that matches your motor foot mount, secure motor pump assembly to shelf top.
• 9/16” wrench and 9/16” socket - (4) 3/8”-16 x 1” Hex Bolts and (4) 3/8” -16 Nylock Nuts
• 1/2” socket - (4) 5/16”-18x3/4” Carriage Bolts and (4) 5/16”-18 Nylock Flange Nut
6
IN
OUT
IN
OUT
IN
OUT
DISCONNECT POWER BEFORE INSTALLING OR SERVICING.
ALL ELECTRICAL WORK SHOULD BE COMPLETED BY QUALIFIED PERSONNEL