SW-2000M-CL-65
24
7.1.4
Saving and restoring the capture settings
7.1.4.1
CS –
show image capture settings
The command CS shows existing settings for this group of commands:
•
SENSOR
•
LINE RATE, LINE PERIOD
•
LINE CTRL
•
LINE IT
•
GAIN
•
OFFSET
•
CL MODE
•
CL RATE
•
READOUT
•
ROI
•
BINNING
•
FFC
7.1.4.2
CS SAVE
–
save settings (1
st
set)
This command stores all the above-mentioned settings to the first location in non-volatile
memory. The settings are loaded at power-up and during reboot of the camera.
7.1.4.3
CS LOAD
–
load settings (1
st
set)
This command restores all the above-mentioned settings from the first memory location of the
non-volatile memory.
Command
Description
CS ?
List of available Capture Settings group commands.
CS
Returns the present Capture Settings.
CS SAVE
Saves the present Capture Settings to the first memory
location. Loaded during reboot and power-up.
CS LOAD
Loads the stored Capture Settings from the first memory
location.
CS SAVE2
Saves the present Capture Settings to the second memory
location.
CS LOAD2
Loads the stored Capture Settings from the second memory
location.
CS FACTORY RESET
Restores the Capture Settings to the factory values and
saves them to the first memory location.