FPGA firmware update
1.
Make sure you have the correct file (.rbf) for the camera model and the existing
configuration available.
2.
Make sure you have a working communication via the Ethernet port.
3.
Make sure you have a compatible web browser and can access the main page
(
http://10.10.10.10
) already before initiating this update.
4.
Check and make a note of the existing configuration. Telnet command: VER.
5.
Save any settings that you want to keep. The camera must be rebooted during the
process.
6.
Access
http://10.10.10.10/FPGAupdate.html
.
7.
Browse and open the file (.rbf). You may cancel the operation now by closing the web
page. Click on Upload to proceed.
Do not interrupt the upload.
8.
The green LED near the power connector should now turn off.
9.
Wait for the user interface page to change. Then click on the ‘HOME’ button. The LED
remains off.
10.
The camera must next be rebooted. You may power cycle the camera or send the
REBOOT command followed by CONFIRM.
11.
Close old communication sessions to the camera and establish new ones as needed.
12.
Verify by command VER that the Logic version has changed as intended.