LUT (Lookup Table)
The LUT function is used to generate a non-linear mapping between signal values
captured on the sensor and those that are output from the camera.
You can specify the output curve using 257 setting points (indexes).
■
To use the LUT function
Configure the settings as follows.
■
LUT Value
LUT values range from 0 at the lowest to 4095 at the highest. Linear interpolation is
used to calculate LUT values between the index points.
Index0 Index1 Index2
LUTValue[0]
LUTValue[1]
LUTValue[2]
Index256
LUTValue[256]
0
4095
*) SP-45001C-CXP2A only
LUT
Control
Item
Setting value /
selectable range
Description
LUTMode
LUT
Use LUT.
LUTSelector* Red, Green, Blue
Select the LUT channel to control.
LUTIndex
0 ~ 256
Select the LUT index to configure. Indexes represent the
possible pixel values captured on the sensor, from the
lowest value (Index 0) to the highest (Index 256). For
example, Index 0 represents a full black pixel and Index
256 represents a full white pixel.
LUTValue
0 ~ 4095
Set the LUT output value for the selected index.
Values between points are determined
using the linear interpolation values of
data to the left and right.
SP-45001M-CXP2A/SP-45001C-CXP2A