Setting range
Default value
Description
Configure sequencer settings.
Off, On
Off
Enable/disable [SequencerMode].
0:TriggerSequencerMode,
1:CommandSequencerMode
TriggerSequencerMode
Select the sequencer mode.
1~128
1
Select the index number to configure.
SequencerWidth
128~8192 step 128
8192
Set the width of the selected SequencerIndex.
SequencerHeight
8~4096 step 4
4096
Set the height of the selected SequencerIndex.
SequencerOffsetX
0~8064 step 128
0
Set the horizontal offset value for the selected SequencerIndex.
SequencerOffsetY
0~4092 step 4
0
Set the vertical offset value for the selected SequencerIndex.
SequencerBinningHorizontal
0, 1
0
For the selected SequencerIndex, set the number of pixels in the horizontal
direction for which to perform binning.
In binning mode, the setting value of BinningHorizontalMode is applied.
SequencerBinningVertical
0, 1
0
For the selected SequencerIndex, set the number of pixels in the vertical
direction for which to perform binning.
In binning mode, the setting of BinningVerticalMode is applied.
SequencerFrameCount
ー
ー
Set the FrameCount value for the selected SequencerIndex.
SequencerExposureTime
1μs ~
ー
Set the exposure time for the selected SequencerIndex.
SequencerGainDigitalAll
x1.0 ~ x16.0
x1.0
Set the GainDigitalAll value for the selected SequencerIndex.
SequencerGainDigitalRed
x0.447~x5.624
x1.0
Set the DigitalRed Gain value for the selected SequencerIndex.
SequencerGainDigitalBlue
x0.447~x5.624
x1.0
Set the DigitalBlue Gain value for the selected SequencerIndex.
SequencerBlackLevelAll
-133~255
0
Set the BlackLevelAll value for the selected SequencerIndex.
SequencerLutEnable
True, False
False
Set the LutEnable value for the selected SequencerIndex.
SequencerSetNext
0 ~ 128
Set the next index to be displayed for the selected SequencerIndex.
(Enabled only for TriggerSequencer.)
If 0 is specified, the operation of Sequencer is stopped.
1~255
1
Set the repeat count for the sequencer.
1~128
1
Displays the sequencer set number.
1~128
1
Specify the first index number to switch to when starting
[TriggerSequencerMode].
1~128
1
Set this to change the SequencerIndex. (Enabled only for
CommandSequencer.)
ー
ー
In [TriggerSequencerMode], reset the current index number to the number
configured in [SequencerSetStart].
Configure counter settings.
(This camera only supports counter functions.)
ー
ー
Select the counter
[Setting range]
0:Counter0, 1:Counter1, 2:Counter2, 3:Counter3
CounterEventSource
ー
Off
Assign the counter event signal for which you want to read the count value
to a dedicated counter, and read the value.
[Setting range]
Counter0 0:Off, 1:FrameTrigger
Counter1 0:Off, 1:ExposureStart
Counter2 0:Off, 1:SensorReadOut
Counter3 0:Off, 1:FrameTransferEnd
CounterEventActivation
ー
ー
Set the count timing.
The setting value is fixed with the following data.
Counter0, Counter1, Counter2 : RisingEdge
Counter3 : FallingEdge
CounterReset
ー
ー
Reset the counter.
CounterValue
0~65535
0
Display the count value.
CounterStatus
ー
ー
Display the counter status.
0: CounterIdle: Idle
1: CounterTriggerWait
2: CounterActive: Counting
3: CounterCompleted:Complete counting
4: CounterOverflow: Count value exceeded the maximum valule.
Configure user settings.
0: Default,
1: UserSet1,
2: UserSet2,
3: UserSet3
Default
Select the user settings.
UserSetLoad
ー
ー
Load user settings.
(If 0 is specified, the factory default setting is read.)
UserSetSave
ー
ー
Save the current setting values as user settings.
(If 0 is specified, UserSetSave is invalid.)
SequencerSetActive
SequencerRepetition
SequencerSetSelector
SequencerModeSelect
SequencerSetStart
UserSetSelector
SequencerReset
SequencerMode
Item
CounterSelector
SequencerCommandIndex
CounterAndTimerControl
UserSetControl
SequencerControl
SP-45000M-CXP4A/SP-45000C-CXP4A